| 5475 |
2005-05-14 02:32:02 |
GX 339-4 |
V821 Ara |
Low Mass X-ray Binary |
undef |
0.8000 |
255.705800 |
-48.789760 |
37439.66 |
Chandra Configuration for the Observation
Zeroth-Order Image
 | |
| The zeroth-order image for GX 339-4 |
Hardness Ratios and Quantiles
Hardness ratios and quantiles are calculated from the predicted ACIS-S or ACIS-I aimpoint spectra, as indicated.
| ACIS-S |
0.425 |
0.705 |
0.869 |
| ACIS-I |
0.458 |
0.789 |
0.916 |
S, M, and H represent the predicted total counts in the following passbands: S: 0.3-0.9 keV M: 0.9-1.5 keV H: 1.5-8.0 keV |
| ACIS-S |
keV |
1.380 |
0.005 |
1.905 |
0.007 |
3.219 |
0.008 |
| Q-norm |
0.140 |
0.001 |
0.208 |
0.001 |
0.379 |
0.001 |
| ACIS-I |
keV |
1.424 |
0.004 |
1.949 |
0.006 |
3.453 |
0.009 |
| Q-norm |
0.146 |
0.001 |
0.214 |
0.001 |
0.409 |
0.001 |
Normalized quantiles (Q-norm) are defined as:
Qx = (Ex - Elo)/(Ehi - Elo) Where Elo = 0.3 keV and Ehi = 8.0 keV. |
Spectral Metrics
A series of line-line, line-continuum, and continuum-continuum ratios calculated from the high-resolution 1st order MEG or LEG spectrum.
| 0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
| 0.0016 |
0.0000 |
0.0000 |
0.0000 |
0.0016 |
0.0000 |
0.0037 |
0.0000 |
0.0038 |
0.0000 |
36.4752 |
0.0227 |
Spectral Fits

Mewe-Kaastra-Liedahl 2-temperature fit of the low-resolution zeroth-order spectrum of GX 339-4.
Warning: The zeroth-order spectrum may be subject to distortions from pileup.
| zeroth-order |
xswabs*(xsmekal1+xsmekal2) |
0.555 |
|
30.000 |
|
0.010 |
|
1.71 |
|
1.93094e-11 |
0 |
2.51 |
455 |

Mewe-Kaastra-Liedahl 2-temperature fit of the predicted low-resolution ACIS-S Aimpoint spectrum of GX 339-4. The predicted spectrum was scaled to 1500 counts.
| ACIS-S |
xswabs*(xsmekal1+xsmekal2) |
0.010 |
|
30.000 |
|
1.000 |
|
0.00 |
|
2.87635e-13 |
0 |
4.69 |
77 |

Mewe-Kaastra-Liedahl 2-temperature fit of the predicted low-resolution ACIS-I Aimpoint spectrum of GX 339-4. The predicted spectrum was scaled to 1500 counts.
| ACIS-I |
xswabs*(xsmekal1+xsmekal2) |
0.010 |
|
30.000 |
|
1.000 |
|
1.50 |
|
3.8388e-13 |
0 |
5.94 |
80 |
HETG Light Curve
 |
| Odds | -2.276 |
| Prob. | 0.005 |
| Var. Index | 0 |
|
HETG light curve for GX 339-4, constructed from all ±1st, ±2nd, and ±3rd order HETG events.
HETG HEG Spectrum
High-Resolution 1st Order HEG Spectrum for GX 339-4
HETG MEG Spectrum
High-Resolution 1st Order MEG Spectrum for GX 339-4
X-Atlas Data Products
Retrieve observation data from the Chandra Data Archive:
WebChaSeR