| 6290 |
2005-06-15 20:35:54 |
GX 339-4 |
V821 Ara |
Low Mass X-ray Binary |
undef |
0.8000 |
255.705810 |
-48.789790 |
21220.51 |
Chandra Configuration for the Observation
Zeroth-Order Image
 | |
| The zeroth-order image for GX 339-4 |
Hardness Ratios and Quantiles
Hardness ratios and quantiles are calculated from the predicted ACIS-S or ACIS-I aimpoint spectra, as indicated.
| ACIS-S |
0.394 |
0.587 |
0.797 |
| ACIS-I |
0.416 |
0.759 |
0.893 |
S, M, and H represent the predicted total counts in the following passbands: S: 0.3-0.9 keV M: 0.9-1.5 keV H: 1.5-8.0 keV |
| ACIS-S |
keV |
1.336 |
0.006 |
1.803 |
0.010 |
2.869 |
0.024 |
| Q-norm |
0.135 |
0.001 |
0.195 |
0.001 |
0.334 |
0.003 |
| ACIS-I |
keV |
1.394 |
0.007 |
1.832 |
0.010 |
3.103 |
0.027 |
| Q-norm |
0.142 |
0.001 |
0.199 |
0.001 |
0.364 |
0.004 |
Normalized quantiles (Q-norm) are defined as:
Qx = (Ex - Elo)/(Ehi - Elo) Where Elo = 0.3 keV and Ehi = 8.0 keV. |
Spectral Metrics
A series of line-line, line-continuum, and continuum-continuum ratios calculated from the high-resolution 1st order MEG or LEG spectrum.
| 0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
0.0000 |
27.7463 |
0.0000 |
5.9724 |
0.0000 |
0.2687 |
0.0000 |
| 0.0766 |
0.0569 |
0.0000 |
0.0000 |
0.0766 |
0.0000 |
0.0168 |
0.0003 |
0.0208 |
0.0003 |
4.1947 |
0.0274 |
Spectral Fits

Mewe-Kaastra-Liedahl 2-temperature fit of the low-resolution zeroth-order spectrum of GX 339-4.
Warning: The zeroth-order spectrum may be subject to distortions from pileup.
| zeroth-order |
xswabs*(xsmekal1+xsmekal2) |
0.215 |
|
21.481 |
|
0.562 |
|
0.68 |
|
6.96225e-12 |
0 |
1.00 |
149 |

Mewe-Kaastra-Liedahl 2-temperature fit of the predicted low-resolution ACIS-S Aimpoint spectrum of GX 339-4. The predicted spectrum was scaled to 1500 counts.
| ACIS-S |
xswabs*(xsmekal1+xsmekal2) |
0.010 |
|
30.000 |
|
1.000 |
|
0.01 |
|
4.91012e-13 |
0 |
6.18 |
76 |

Mewe-Kaastra-Liedahl 2-temperature fit of the predicted low-resolution ACIS-I Aimpoint spectrum of GX 339-4. The predicted spectrum was scaled to 1500 counts.
| ACIS-I |
xswabs*(xsmekal1+xsmekal2) |
0.010 |
|
30.000 |
|
1.000 |
|
0.33 |
|
7.19085e-13 |
0 |
3.84 |
77 |
HETG Light Curve
 |
| Odds | -1.785 |
| Prob. | 0.016 |
| Var. Index | 0 |
|
HETG light curve for GX 339-4, constructed from all ±1st, ±2nd, and ±3rd order HETG events.
HETG HEG Spectrum
High-Resolution 1st Order HEG Spectrum for GX 339-4
HETG MEG Spectrum
High-Resolution 1st Order MEG Spectrum for GX 339-4
X-Atlas Data Products
Retrieve observation data from the Chandra Data Archive:
WebChaSeR