FP_TEMP temperatures check

Summary

Date start 2019:055:09:36:00.000
Date stop 2019:063:08:09:35.419
FP_TEMP status NOT OK
Load directory /data/acis/LoadReviews/2019/FEB2519/ofls
Run time Wed Feb 20 20:22:51 2019 by acisdude
Run log run.dat
Temperatures temperatures.dat
Earth Solid Angles earth_solid_angles.dat
States states.dat

ACIS-I FP_TEMP -114 deg C Violations

Date start Date stop Max temperature Obsids
2019:059:12:50:46.816 2019:059:12:56:14.816 -113.76 22124
2019:059:13:01:42.816 2019:059:13:07:10.816 -113.97 22124
2019:062:09:49:02.816 2019:062:10:27:18.816 -113.96 22125

No ACIS-S -112 deg C FP_TEMP Violations

FP TEMP Sensitive, -118.7 deg. C Preference Not Met:

Date start Date stop Max temperature OBSID
2019:055:20:33:34.816 2019:056:00:28:38.816 -116.14 22136
2019:061:02:44:54.816 2019:061:05:56:14.816 -116.07 20921
2019:061:15:41:10.816 2019:061:15:41:10.816 -114.68 22129
2019:061:15:46:38.816 2019:062:00:25:58.816 -114.00 22129
2019:062:19:33:58.816 2019:062:21:28:46.816 -117.31 20590

No ECS Observation -118.7 deg C FP_TEMP Violations

fptempM120toM111.png pow_sim.png roll_taco.png

FP_TEMP Model Validation

MSID quantiles

MSID 1% 5% 16% 50% 84% 95% 99%
FPTEMP -1.25 -0.91 -0.24 0.08 0.96 1.56 2.23
PITCH -5.521 -0.265 -0.183 -0.007 0.187 0.254 4.898
TSCPOS -1 -1 -1 0 0 1 1
ROLL -1.451 -0.965 -0.401 -0.094 0.448 0.571 1.638

Validation Violations

MSID Quantile Value Limit
PITCH 1 -5.521 3.00
PITCH 99 4.898 3.00

FPTEMP

Red = telemetry, blue = model

fptemp_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

fptemp_valid_hist_log.png fptemp_valid_hist_lin.png

PITCH

Red = telemetry, blue = model

pitch_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

pitch_valid_hist_log.png pitch_valid_hist_lin.png

TSCPOS

Red = telemetry, blue = model

tscpos_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

tscpos_valid_hist_log.png tscpos_valid_hist_lin.png

ROLL

Red = telemetry, blue = model

roll_valid.png

Data for FPTEMP residual plots limited between -120.0 and -112.0 deg. C

roll_valid_hist_log.png roll_valid_hist_lin.png

ADDITIONAL PLOTS

Additional plots of FPTEMP vs TIME for different temerature ranges

fptempM120toM119.png fptempM120toM90.png