Instrument Safing Action SCSs
These SCSs are stored on-board in the protected SCS area.
For HRC, these are the flight SCSs, not Thermal Vac Testing SCSs.
Safing SCSs |
Status |
SIM Move to Safe Position SCS |
100% complete |
OTG Emergency Retract |
100% complete |
ACIS Radiation High Commands |
100% complete |
ACIS Radiation Low Commands |
100% complete |
HRC Radiation High Commands |
100% complete. Combines both HRC-I and HRC-S HV Reduction Sequence |
HRC Radiation Low Commands |
100% complete (actually an empty SCS at this time) |
HRC Scheduled / No Dither HRC-I HV Ramp Down* |
100% complete |
HRC Scheduled / No Dither HRC-S HV Ramp Down* |
100% complete |
HRC Scheduled / Dither HRC-I HV Ramp Up |
100% complete |
HRC Scheduled / Dither HRC-S HV Ramp Up |
100% complete |
HRC Dither Control SCS |
TBS by Dan Muleady |
* At this time, the voltage reduction steps are the same as for the HRC Radiation High Command Sequence.
SIM Move to Safe Position SCS
This SCS positions the SIM so that the x-ray focal point is between the ACIS and HRC detectors
The command mnemonics have been changed in the IPCL, and are not reflected here (yet).
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
3TSCMBEN |
SIM TSC MOTOR ENABLE |
|
|
|
|
|
|
3SIMGOTO |
SIM GO TO POSITION |
|
|
|
|
Allow 4 minutes for SIM movement. |
|
|
SIM Address Sign |
SIMGOTO1 |
|
0 |
|
2’s complement for sign, 1 = minus |
|
|
SIM Address Magnitude |
SIMGOTO2 |
|
00101101100101 |
|
Go-to-Position: Initiates movement of one of the drive motors. Destination position for motor movement is a signed number representing a mechanism position relative to the origin. The sign determines the direction of motion. Positive numbers cause the SIM to move in the +X (FA) or -Z (TSC) direction (focus point moves in +Z direction).
The SIM safe position is presently +23336 hall steps. Hall steps are divided by 8 then converted to binary for input into the SIM Address Magnitude. |
00:04:00.000 |
3TSCMBDS |
SIM TSC MOTOR DISABLE |
|
|
|
|
Disable motor after 4 minutes |
00:00:00.064 |
COSCSEND |
End SCS |
|
|
|
|
|
OTG Emergency Retract
This SCS retracts whatever OTG may be inserted using MCE hardware commands.
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
4MC5AEN |
MCE A: ENAB 5 VOLT DC/DC CONV |
|
|
|
|
Enable logic power |
00:00:01.000 |
4MC5AEN |
MCE A: ENAB 5 VOLT DC/DC CONV |
|
|
|
|
Enable logic power |
00:00:01.000 |
4SLHGAEN |
MCE A: CONFIG HETG DRIVE LOGIC TO: SELECT |
|
|
|
|
Select HETG |
00:00:01.000 |
4SLHGAEN |
MCE A: CONFIG HETG DRIVE LOGIC TO: SELECT |
|
|
|
|
Select HETG |
00:00:01.000 |
4RTHGAEN |
MCE A: CONFIGURE HETG DRIVE LOGIC TO: RETRACT |
|
|
|
|
Select Retract |
00:00:01.000 |
4RTHGAEN |
MCE A: CONFIGURE HETG DRIVE LOGIC TO: RETRACT |
|
|
|
|
Select Retract |
00:00:01.000 |
4MC28AEN |
MCE A: ENAB 28 VOLT DC/DC CONV |
|
|
|
|
Enable Motor Power |
00:00:01.000 |
4MC28AEN |
MCE A: ENAB 28 VOLT DC/DC CONV |
|
|
|
|
Enable Motor Power |
00:00:01.000 |
4EXHGAEN |
MCE A: EXEC HETG INSERTION/RETRACTION |
|
|
|
|
COMMAND TO INITIATE OTG TRANSISTION |
00:03:30.000 |
4EXHGAEN |
MCE A: EXEC HETG INSERTION/RETRACTION |
|
|
|
|
COMMAND TO INITIATE OTG TRANSISTION |
00:00:01.000 |
4EXHGBDS |
MCE B: DISA HETG INSERTION/RETRACTION |
|
|
|
|
Disable OTG Transition |
00:00:01.000 |
4EXHGBDS |
MCE B: DISA HETG INSERTION/RETRACTION |
|
|
|
|
Disable OTG Transition |
00:00:01.000 |
4MC28ADS |
MCE A: DISA 28 VOLT DC/DC CONV |
|
|
|
|
Disable Motor Power |
00:00:01.000 |
4MC28ADS |
MCE A: DISA 28 VOLT DC/DC CONV |
|
|
|
|
Disable Motor Power |
00:00:01.000 |
4SLLGAEN |
MCE A: CONFIG LETG DRIVE LOGIC TO: SELECT |
|
|
|
|
Select LETG |
00:00:01.000 |
4SLLGAEN |
MCE A: CONFIG LETG DRIVE LOGIC TO: SELECT |
|
|
|
|
Select LETG |
00:00:01.000 |
4RTLGAEN |
MCE A: CONFIGURE LETG DRIVE LOGIC TO: RETRACT |
|
|
|
|
Select Retract |
00:00:01.000 |
4RTLGAEN |
MCE A: CONFIGURE LETG DRIVE LOGIC TO: RETRACT |
|
|
|
|
Select Retract |
00:00:01.000 |
4MC28AEN |
MCE A: ENAB 28 VOLT DC/DC CONV |
|
|
|
|
Enable Motor Power |
00:00:01.000 |
4MC28AEN |
MCE A: ENAB 28 VOLT DC/DC CONV |
|
|
|
|
Enable Motor Power |
00:00:01.000 |
4EXLGAEN |
MCE A: EXEC LETG INSERTION/RETRACTION |
|
|
|
|
COMMAND TO INITIATE OTG TRANSISTION |
00:03:30.000 |
4EXLGAEN |
MCE A: EXEC LETG INSERTION/RETRACTION |
|
|
|
|
COMMAND TO INITIATE OTG TRANSISTION |
00:00:01.000 |
4EXLGADS |
MCE A:DISA LETG INSERTION/RETRACTION |
|
|
|
|
Disable OTG transition |
00:00:01.000 |
4EXLGADS |
MCE A:DISA LETG INSERTION/RETRACTION |
|
|
|
|
Disable OTG transition |
00:00:01.000 |
4MC28ADS |
MCE A: DISA 28 VOLT DC/DC CONV |
|
|
|
|
Disable Motor Power |
00:00:01.000 |
4MC28ADS |
MCE A: DISA 28 VOLT DC/DC CONV |
|
|
|
|
Disable Motor Power |
00:00:01.000 |
4MC5ADS |
MCE A: DISA 5 VOLT DC/DC CONV |
|
|
|
|
Disable Logic Power |
00:00:01.000 |
4MC5ADS |
MCE A: DISA 5 VOLT DC/DC CONV |
|
|
|
|
Disable Logic Power |
00:00:00.064 |
COSCSEND |
End SCS |
|
|
|
|
|
ACIS Radiation High Commands
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
1RMONIRM |
DPA RADIATION MONITOR |
|
|
|
|
|
|
|
BEP STATUS REGISTER BIT RAD_MON |
1RMONIR1 |
|
1 |
|
SETS BEP STATUS REGISTER BIT RAD_MON TO VALUE=D(0). THIS BIT DEFAULTS TO 0 UPON POWER-UP. |
|
|
|
|
Verifier Missing |
|
|
|
00:00:00.064 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
ACIS Radiation Low Commands
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
1RMONIRM |
DPA RADIATION MONITOR |
|
|
|
|
|
|
|
BEP STATUS REGISTER BIT RAD_MON |
1RMONIR1 |
|
0 |
|
SETS BEP STATUS REGISTER BIT RAD_MON TO VALUE=D(0). THIS BIT DEFAULTS TO 0 UPON POWER-UP. |
|
|
|
|
Verifier Missing |
|
|
|
00:00:00.064 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Radiation High Commands
HRC Radiation Monitor High Sequence:
This command sequence is used for radiation alert ramp-down and EPHIN Failure Ramp Down.
4 steps in the HRC radiation monitor SCS:
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:01.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
The next two commands disable the on-board SCSs that ramp up the MCP HV in response to daily load ATS commands. These commands can be excluded if the SCS is not stored on-board. |
|||||||
00:00:00.064 |
CODISASX |
DISABLE SCS# |
|
|
|
|
|
|
|
CODISASX - SCS NUMBER |
CODISAS1 |
|
Supply # |
|
Disable HRC-I Ramp Up SCS |
00:00:00.064 |
CODISASX |
DISABLE SCS# |
|
|
|
|
|
|
|
CODISASX - SCS NUMBER |
CODISAS1 |
|
Supply # |
|
Disable HRC-S Ramp Up SCS |
00:00:00.064 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Radiation Low Commands
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Scheduled / No Dither HRC-I HV Ramp Down
This command sequence is used for scheduled and no dither HV ramp-down
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:00.064 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Scheduled / No Dither HRC-S HV Ramp Down
This command sequence is used for scheduled and no dither HV ramp-down
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:01.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:01.000 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Scheduled / Dither HRC-I HV Ramp Up
This command sequence is used for scheduled and dither HV ramp-up
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:00.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
53 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
42 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
61 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
61 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
50 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
50 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
68 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
68 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
57 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
57 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
76 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
76 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
65 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
65 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
83 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
83 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
72 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
72 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2IMCLDS |
IMAGING HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
91 |
|
|
00:00:01.000 |
2IMTBHV |
IMAGING DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTBHV2 |
|
91 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
79 |
|
|
00:00:01.000 |
2IMTTHV |
IMAGING DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2IMTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2IMTTHV2 |
|
79 |
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2IMCLEN |
IMAGING HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:00.064 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|
HRC Scheduled / Dither HRC-S HV Ramp Up
This command sequence is used for scheduled and dither HV ramp-up
Delta-T |
Command Mnemonic |
Description |
Data Parameters |
Telemetry Verifier(s) |
Expected Value |
Units |
Notes |
00:00:00.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:00.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
54 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
43 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
64 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
64 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
53 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
53 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
74 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
74 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
63 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
63 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
84 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
84 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
73 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
73 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
94 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
94 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
83 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
83 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:30.000 |
2SPCLDS |
SPECT HV CURRENT LIMIT DISABLE |
|
|
|
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
102 |
|
|
00:00:01.000 |
2SPTBHV |
SPECT DET BOTTOM PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTBHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTBHV2 |
|
102 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
90 |
|
|
00:00:01.000 |
2SPTTHV |
SPECT DET TOP PLATE HV SETTING |
|
|
|
|
|
|
|
FILLER |
2SPTTHV1 |
|
|
|
|
|
|
VOLTAGE STEPS |
2SPTTHV2 |
|
90 |
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:02.000 |
2SPCLEN |
SPECT HV CURRENT LIMIT ENABLE |
|
|
|
|
|
00:00:01.000 |
COSCSEND |
END SCS (SCS ONLY) |
|
|
|
|
|