SOT Shift Report 2011-03-14 L4253 Duration: 14 Mar 2011 08:30 EDT - 14 Mar 2011 09:30 EDT 14 Mar 2011 12:30 GMT - 14 Mar 2011 13:30 GMT SOT Lead: Tom Aldcroft ======================================== Plan ---- Continue with the MAR1411C loads: GG_02 CAL-ER (55594) 2011:073:16:05:22.707 0.0 -- -- G1_02 CAL-ER (55593) 2011:073:16:46:52.622 0.0 -- -- G2_02 CAL-ER (55592) 2011:073:17:11:02.670 2.0 -- -- G3_02 CAL-ER (55591) 2011:073:19:49:00.000 0.5 -- -- T_X03 CAL-ER (55590) 2011:073:21:31:49.838 0.1 -- -- 12935 AKARI-NEP-Deep Fie 2011:074:00:45:00.838 17.0 ACIS-I NONE 13206 Crab 2011:074:06:04:08.478 5.0 ACIS-S NONE 13031 Vega 2011:074:08:09:14.119 2.0 HRC-I NONE 13032 Vega 2011:074:08:51:10.367 2.0 HRC-S NONE 13033 Vega 2011:074:09:33:00.367 1.0 HRC-S NONE 13034 Vega 2011:074:09:58:10.367 1.0 HRC-S NONE 13035 Vega 2011:074:10:23:20.367 1.0 HRC-S NONE 13046 HZ43 2011:074:11:10:01.615 2.0 HRC-I LETG 12993 M83 2011:074:12:22:28.557 50.0 ACIS-S NONE Events ------ 1225 BOT on DSS-27 GOLDSTONE 1325 EOT Notes from 9am meeting ---------------------- Ops: - Nominal - No detailed ops status today due to issue with OCCweb external connectivity. MP: - MAR2111A expected out early this week. Radiation: - Solar Activity Forecast: Solar activity is expected to be low with a chance for an M-class event. - Geophysical Activity Forecast: The geomagnetic field is expected to be quiet to unsettled with a chance for isolated active levels for day one (14 March). Days two and three (15-16 March) are expected to be predominately quiet as the effects from the coronal hole high speed stream subside. IST: - On Saturday during a planned power outage at the OCC the UPS failed to transfer power from the house to the generator resulting in a hard shutdown of all systems. - Teams worked through the weekend to recover. - Systems are now supporting nominal operations, with some residual issues (e.g. OccWeb external interface down) still being worked. - Currently running on house power with no ability to automatically transition to generatory. Power Resources will be on-site to investigate / repair the UPS. Quicklooks ---------- - Quicklooks from the last week were reviewed and there are no issues (apart from the widely discussed lack of events from ACIS I0 in 12934). Snapshot -------- UTC 2011:073:13:24:08 (Mar14) f_ACE 3.88e+01 F_CRM 3.71e+08 Kp 1.3 R km 69539D OBT 2011:073:13:20:59 CTUVCDU 16354175 OBC s/w NRML FMT2_NORM CPEstat NORM OBT 416496059.49 ONLVCDU 16354168 OBC Errs 0 OBSID 13135 EPState SUN SIM TTpos 91751 HETG Angle 79.09 PCADMODE NPNT RA 49.478 Bus V 29.61 SIM FApos -535 LETG Angle 77.21 PCONTROL NPNT Dec -44.233 Bus I 24.17 AOFSTAR GUID Roll 246.804 ACA Object FFFSSSSS Dither ENAB HRC-I HV ON ACA ImFunc TTTTTTTT Dith Yang 6.14 Yaw Rate 0.17 HRC-S HV OFF ACA CCD Temp -19.0 Dith Zang -6.69 Pitch Rate -0.00 SHLD HV 8.0 ACA Int Time 1.698 Roll Rate 0.11 EVT RT 0 AOACSTAT OK FSS SunBeta SUN SHLD RT 17 FSS Alfa -0.86 Batt 1 SOC 100.00% Avg HRMA Temp 70.65 FSS Beta 25.65 Batt 2 SOC 100.00% ACIS Stat7-0 65 Avg OBA Temp 59.97 SA Resolv 64.26 Batt 3 SOC 100.00% Cold Rad -127.9 OBA Tavg Fault NFLT SA Sun Pres ILLM Warm Rad -86.9 OBA Trng Fault NFLT +Y SA Amps 11.79 RadMon ENAB HRMA power 5.90 SCS 128 ACT -Y SA Amps 11.98 EPHIN Geom VLD OBA power 70.20 SCS 129 ACT +Y SA Temp 115.85 E150 125.0 SCS 130 ACT -Y SA Temp 116.58 E300 98.0 Roll Mom. -1.144 SCS 107 INAC E1300 78.0 Pitch Mom. -10.131 UpL Cmd Acc 18615 EPH A-Leak 1.0200 Yaw Mom. 3.941 Cmd Rej A 254 EPH B-Leak 1.0200 PMTANKP 175.711 EPH temp 102.38 Gyro 2 Curr 1 124.80 Roll Bias -0.5826 EPH 27I 7.27 M Unload MON Gyro 2 Curr 2 105.60 Pitch Bias -1.7046 TSC Move STOP Prop. line 03 138.53 Yaw Bias -0.7649 CTX B PWR 36.73 FA Move STOP Prop. line 04 107.02 CTX B Volts 3.54 OTG Move DISA