ACIS SOT Shift report M3043 Nov 19, 2007 16:15 EDT, 2007:323:21:15 GMT COMM Periods: = 2007 Nov 19 4:15 pm EST = 2007 Nov 19 6:10 pm EST See http://asc.harvard.edu/acis/SOT_reports/sot_shift.html or /proj/web-cxc/htdocs/acis/SOT_reports/Nov_19_2007_M3043_acis.txt ACIS Personnel: Paul Plucinsky, Royce Bueher PLAN: ----- We plan to continue monitoring the ACIS detector housing cooling test that is being performed during the perigee passage. During this COM we expect the load to command the side B DH heater on at 323:21:30 SUMMARY: ------- Comm came up on schedule. The telemetry seen was: 21:15 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.88 (value of the mean over 10 samples) 1DAHBVO= 0.0 (value of the mean over 10 samples) 1DAHBCU= 0.0 (value of the mean over 10 samples) 1CBBT= -69.8 (value of the mean over 10 samples) 1CBAT= -69.8 (value of the mean over 10 samples) 1WRBT= -86.9 (value of the mean over 10 samples) 1WRAT= -86.9 (value of the mean over 10 samples) 21:35 TLM indicates that the DH heater on side B has come on. 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.88 (value of the mean over 10 samples) 1DAHBVO= 25.6 (value of the mean over 10 samples) 1DAHBCU= 1.60 (value of the mean over 10 samples) 1CBBT= -62.4 (value of the mean over 10 samples) 1CBAT= -67.3 (value of the mean over 10 samples) 1WRBT= -86.9 (value of the mean over 10 samples) 1WRAT= -86.9 (value of the mean over 10 samples) 22:00 monitoring the Camera Body temperatures 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.1 (value of the mean over 10 samples) 1DAHBVO= 13.1 (value of the mean over 10 samples) 1DAHBCU= 1.0 (value of the mean over 10 samples) 1CBBT= -62.4 (value of the mean over 10 samples) 1CBAT= -62.4 (value of the mean over 10 samples) 1WRBT= -84.4 (value of the mean over 10 samples) 1WRAT= -84.4 (value of the mean over 10 samples) 23:00 monitoring the Camera Body temperatures 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.1 (value of the mean over 10 samples) 1DAHBVO= 8.7 (value of the mean over 10 samples) 1DAHBCU= 0.6 (value of the mean over 10 samples) 1CBBT= -59.9 (value of the mean over 10 samples) 1CBAT= -62.4 (value of the mean over 10 samples) 1WRBT= -82.0 (value of the mean over 10 samples) 1WRAT= -82.0 (value of the mean over 10 samples) The Camera Body temperatures have returned to the normal operating temperatures.