ACIS SOT Shift report M3009 Oct 17, 2007 12:40 EDT,2007:290:16:40 GMT COMM Period: = 2007 Oct 17 12:40 pm EDT End = 2007 Oct 17 2:40 pm EDT See http://asc.harvard.edu/acis/SOT_reports/sot-shift.html or /proj/web-cxc/htdocs/acis/SOT_reports/Oct_17_2007_M3009_acis.txt ACIS Personnel: Joseph DePasqule PLAN: ---- We plan to monitor the ACIS detector housing cooling test that is being performed during the Chandra Deep Field South observation (OBSID 8597). The command to turn off the heater was executed in the load at: 2007:290:06:56:40.593 COMMAND_HW 1HHTRBOF and the heater will be turned on again at: 2007:290:22:01:41.530 COMMAND_HW 1HHTRBON for a total of about 53 ks of cooling time. SUMMARY: ------- At 12:40 EDT, we aquired signal and by 12:45 had seen enough telemetry to be certain that the detector housing heater was indeed turned off in the load and the camera body temperature had cooled to -67.3 C on side A and was toggling between -65.3 C and -67.3 C on side B. Both sides of the camera body temperature settled at -67.3 C by the end of the comm. The telemetry seen was: 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.84 (value of the mean over 10 samples) 1DAHBVO= 0.00 (value of the mean over 10 samples) 1DAHBCU= 0.00 (value of the mean over 10 samples) 1CBBT= -67.3 (value of the mean over 10 samples) 1CBAT= -67.3 (value of the mean over 10 samples) 1WRBT= -84.5 (value of the mean over 10 samples) 1WRAT= -84.5 (value of the mean over 10 samples)