ACIS SOT Shift report M3011 Oct 19, 2007 6:50 EDT,2007:292:22:50 GMT COMM Period: = 2007 Oct 19 6:50 pm EDT End = 2007 Oct 19 8:20 pm EDT (extended to 8:50) See http://asc.harvard.edu/acis/SOT_reports/sot-shift.html or /proj/web-cxc/htdocs/acis/SOT_reports/Oct_19_2007_M3011_acis.txt ACIS Personnel: Joseph DePasqule PLAN: ---- We plan to monitor the ACIS detector housing cooling test that is being performed during the Chandra Deep Field South observation (OBSID 8595). The command to turn off the heater was executed in the load at: 2007:292:14:02:39.122 COMMAND_HW 1HHTRBOF and the heater will be turned on again at: 2007:293:21:02:21.777 COMMAND_HW 1HHTRBON for a total of about 117 ks of cooling time. SUMMARY: ------- There were some problems aquiring signal at the beginning of the COM pass. By 7:10pm EDT, we had a strong signal and verified that the detector housing side B heater had indeed been turned off in the load. Both A and B side camera body temperatures had cooled to -67.3 C and remained there for the duration of the COM pass. The telemetry seen was: 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.84 (value of the mean over 10 samples) 1DAHBVO= 0.00 (value of the mean over 10 samples) 1DAHBCU= 0.00 (value of the mean over 10 samples) 1CBBT= -67.3 (value of the mean over 10 samples) 1CBAT= -67.3 (value of the mean over 10 samples) 1WRBT= -84.5 (value of the mean over 10 samples) 1WRAT= -84.5 (value of the mean over 10 samples)