ACIS SOT Shift report L3012 Oct 19, 2007 10:50 EDT, 2007:293:02:50 GMT COMM Period: = 2007 Oct 19 10:50 pm EDT End = 2007 Oct 20 12:50 am EDT (extended to 1:20) See http://asc.harvard.edu/acis/SOT_reports/sot-shift.html or /proj/web-cxc/htdocs/acis/SOT_reports/Oct_20_2007_L3012_acis.txt ACIS Personnel: Joseph DePasqule PLAN: ---- We plan to continue monitoring the ACIS detector housing cooling test that is being performed during the Chandra Deep Field South observation (OBSID 8595). The command to turn off the heater was executed in the load at: 2007:292:14:02:39.122 COMMAND_HW 1HHTRBOF and the heater will be turned on again at: 2007:293:21:02:21.777 COMMAND_HW 1HHTRBON for a total of about 117 ks of cooling time. SUMMARY: ------- Both sides of the camera body temperature still read -67.3 C at the start of the COM and maintained that temperature through the end of COM. The telemetry seen was: 1DAHTBEN=EN 1DAHTBON=OFF 1DAHHBVO= 28.84 (value of the mean over 10 samples) 1DAHBVO= 0.00 (value of the mean over 10 samples) 1DAHBCU= 0.00 (value of the mean over 10 samples) 1CBBT= -67.3 (value of the mean over 10 samples) 1CBAT= -67.3 (value of the mean over 10 samples) 1WRBT= -84.5 (value of the mean over 10 samples) 1WRAT= -84.5 (value of the mean over 10 samples)