Sep_09_1999_M50.txt Shift M50 Start at 1999:252:18:00 GMT = 1999 Sep 09 02:00pm EDT End 1999 Sep 09 10:00pm EDT SOT Lead Ed Kellogg FOT-SI Andy Northrup ACIS Paul Plucinsky, Yousaf Butt, Ed Boughan HRC-SI John Chappell (Times: hhmm or ddd:hhmm, not precise.) Plan: Execute CAPs 394 for fid search box shrink, 396-8 for ACIS anomaly diagnostics, while continuing with p12d load. Comm break between 1900-2300 deleted. EVENTS PLAN DONE OBSID -------------- ---- ---- ----- AOS not successful 1745 AOS 1921 1244 CAP 394 to shrink fid search boxes to 20" 1943 Start CAP 396, ACIS raw frame diagnostic 1946 Sent new obsid 2107 62413 To format 2, collecting ACIS data; ACA has 3 fids, 5 stars 2109 ACIS stop science 2225 ACA successfully acquired 3 fids, 5 stars with new fid box 2230 1169 Start CAP 398 2235 Format 2 2245 OBSID change 2247 62411 Begin advance uploads for CAP 397 2316 New OBSID 2345 62410 Complete CAP 397 day 253 0025 LOS 0030 NOTES/ISSUES/PROBLEMS --------------------- Rob reports no problems with ACA with Earth as close as 8 degrees. Problem with ground system causes delay in AOS from 1745 to 1921. Much delay in executing CAP 396 due to additional DSN problems. We got thru step 4 of CAP 396, then had a long outage, resumed step 4b at 2107. We did not go back to fmt1, nor do obsid 62412, because 1244 ran so long. ACIS diagnostic run, CAP 396, obsid 62413 shows a charge transfer problem in front illuminated chip. We continued with CAP 398, Timed Exposure of Chips S2, S3, to further explore the ACIS anomaly, using obsids 62411 & 62410. Then we did CAP 397, Run all 10 Video Boards; Warm Boot; Do a DEA Housekeeping Run; Leave ACIS in S-array EVT-histogram.