Shift report M176 January 15 2000, GMT 15:00:00, EDT January 15, 2000 09:00 PLAN: Execute CAP 543 to reset the ACIS Focal Plane. SUMMARY: The bad news is that we appear to have really bottomed out at -123 C. Dave Balke reports from the overnight pass that the focal plane was at -122.6 C at 015:07:00 and we are at -122.0 at the beginning of this pass. The focal plane setpoint was set to -130 C. Before Christmas, we set the focal set point at -126 C and achieved a temperature of -122.9 C. Sigh Once again all the ACIS realtime activities went "exactly as planned." 1) CAP 543 sends one command to change the focal plane setpoint to -110 C. The command was sent at 015:14:22. 2) ACIS temperatures Realize these are hard to interpret because the Focal Plane temperature readouts are backlogged in the TLM stream whereas the other temperature reflect the current value. GMT FP Temp 1CR[AB]T 1WR[AB]T 1CB[AB]T 015:07:00 -122.6 -130.3/-130.3 -82.0/-82.0 -62.4/-59.9 ** overnight pass ** 015:14:00 AOS on DSN 27 (Goldstone 34m) 015:14:02 TLM is ratty, DSN has trouble locking on 015:14:04 OC change spacecraft to a lower bit rate and DSN locks on 015:14:05 NA -130.3/-127.9 -82.0/-82.0 -62.4/-59.9 ** focal plane not available yet because we are in FMT 1 ** 015:14:22 Enable and activate SCS 255 015:14:38 -122.0 -127.9/-127.9 -82.0/-82.0 -62.4/-59.9 ** Finally a DeaHousekeeping packet, So, we appear to have warmed up to -122.0 from -122.6 AFTER the CCDs started clocking ** 015:14:46 verify receipt of changeSysConfig to set focal plane to -110 C 015:15:09 Switch to FMT 2 015:15:11 verify stopScience at 015:15:08 015:15:12 -109.4 -123.1/-123.1 -82.0/-82.0 -62.4/-59.9 ** these are now current, WOW the focal plane warmed up from -122.0 to -109.4 C in 50 minutes ! 015:15:20 -109.2 -123.1/-123.1 -82.0/-82.0 -62.4/-59.9 015:15:32 verify LETG retraction 015:15:34 verify SIM move to ACIS-S 015:15:38 verify startScience for OBSID 400, I2,I3, S2-S4 up 015:15:40 -109.2 -120.7/-120.7 -82.0/-82.0 -62.4/-59.9 015:16:00 LOS NOTES: For those of you who were wondering, the air conditioning in the ACIS room still works. Unbelievable. PROBLEMS: Chandra snapshot is not available. ACIS: Paul Plucinsky, Anya Plucinsky