ACIS LOAD REVIEW OUTPUT:
FOR REVIEW BY CXC ACIS OPS PERSONNEL
-------------------------------------------------
USING /data/acis/LoadReviews/2018/OCT2118/oflsb/CR294_2219.backstop
LOAD HISTORY FROM: /data/acis/LoadReviews/2018/OCT2118/oflsb/ACIS-History_edit.txt
-- CHANDRA LOAD START --
CHANDRA STATUS ARRAY AT START OF LOAD REVIEW (FROM PREVIOUS LOAD HISTORY FILE):
(FP SI,HETG status,LETG status,current OBSID,RadMon status,current TLM FMT,Dither)
= (HRC-S,HETG-OUT,LETG-OUT,21871,OORMPDS,CSELFMT2,ENAB)
2018:294:22:27:00.000 3171370 ACISPKT AA00000000
2018:294:22:27:03.000 3171382 ACISPKT AA00000000
2018:294:22:28:02.000 3171612 COMMAND_SW OORMPEN
==> Exit leg pad time is 25482.48 ks.
>>>ERROR: RadMon EN occurs well after an E1 exit (>15ks).
-OR- RadMon EN encountered prior to a XE1RADZ0/XEF1000.
2018:294:22:29:00.000 3171838 ACISPKT WSFTNEG121
2018:294:22:29:10.000 3171877 ACISPKT RS_0000001
2018:294:22:30:00.000 3172072 MP_OBSID 48918
==> ObsID change occurs 2.9 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 48918:
No ocat info found for obsid 48918
2018:294:22:33:00.000 3172775 ACISPKT AA00000000
2018:294:22:33:04.000 3172790 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:294:22:34:07.000 3173036 ACISPKT RS_0000001
2018:294:22:41:46.917 3174831 AOENDITH AOENDITH
==> DITHER ENABLED
2018:294:23:03:57.917 3180025 MP_OBSID 48917
==> ObsID change occurs 31.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48917:
No ocat info found for obsid 48917
2018:294:23:33:00.000 3186824 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2018:294:23:34:03.000 3187070 ACISPKT RS_0000001
2018:294:23:38:20.232 3188073 MP_OBSID 48916
LATEST OCAT INFO FOR OBSID 48916:
No ocat info found for obsid 48916
2018:295:00:12:35.481 3196094 MP_OBSID 48915
LATEST OCAT INFO FOR OBSID 48915:
No ocat info found for obsid 48915
2018:295:00:44:50.679 3203646 MP_OBSID 48914
LATEST OCAT INFO FOR OBSID 48914:
No ocat info found for obsid 48914
2018:295:01:19:22.397 3211731 COMMAND_HW CSELFMT1
2018:295:01:19:22.397 3211731 MP_OBSID 21911
LATEST OCAT INFO FOR OBSID 21911:
No ACIS info found for obsid 21911.
This is an HRC-I observation.
2018:295:01:19:22.397 3211731 SIMTRANS -50504 (HRC-I)
2018:295:01:22:05.797 3212368 SIMFOCUS -716
2018:295:01:25:51.899 3213251 ACISPKT WSVIDALLDN
2018:295:01:26:09.899 3213321 ACISPKT WSPOW08E1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I1 I2 I3 S3
2018:295:01:27:12.899 3213567 ACISPKT RS_0000001
2018:295:01:27:16.899 3213582 ACISPKT RH_0000001
2018:295:01:27:39.899 3213672 ACISPKT WT00D06014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00d06014
fepCcdSelect = 10 7 1 2 3 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 3 # BEP_TE_MODE_EVHIST
recomputeBias = 1
trickleBias = 0
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 33
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
windowSlotIndex = 65535
2018:295:01:27:43.899 3213688 ACISPKT XTZ0000005
====> CHANDRA STATUS ARRAY=(HRC-I,HETG-OUT,LETG-OUT,21911,OORMPEN,CSELFMT1,ENAB)
2018:295:04:24:50.899 3255159 MP_OBSID 21912
>>>ERROR: The OBSID change to 21912 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21912:
No ACIS info found for obsid 21912.
This is an HRC-I observation.
2018:295:04:50:00.899 3261052 MP_OBSID 21913
>>>ERROR: The OBSID change to 21913 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21913:
No ACIS info found for obsid 21913.
This is an HRC-I observation.
2018:295:05:15:10.899 3266944 MP_OBSID 21914
>>>ERROR: The OBSID change to 21914 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21914:
No ACIS info found for obsid 21914.
This is an HRC-I observation.
2018:295:05:40:20.899 3272837 MP_OBSID 21915
>>>ERROR: The OBSID change to 21915 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21915:
No ACIS info found for obsid 21915.
This is an HRC-I observation.
2018:295:06:05:30.899 3278730 MP_OBSID 21916
>>>ERROR: The OBSID change to 21916 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21916:
No ACIS info found for obsid 21916.
This is an HRC-I observation.
2018:295:07:37:20.899 3300232 MP_OBSID 21917
>>>ERROR: The OBSID change to 21917 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21917:
No ACIS info found for obsid 21917.
This is an HRC-I observation.
2018:295:08:02:30.899 3306125 MP_OBSID 21918
>>>ERROR: The OBSID change to 21918 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21918:
No ACIS info found for obsid 21918.
This is an HRC-I observation.
2018:295:08:27:40.899 3312017 MP_OBSID 21919
>>>ERROR: The OBSID change to 21919 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21919:
No ACIS info found for obsid 21919.
This is an HRC-I observation.
2018:295:08:52:50.899 3317910 MP_OBSID 21920
>>>ERROR: The OBSID change to 21920 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21920:
No ACIS info found for obsid 21920.
This is an HRC-I observation.
2018:295:09:18:00.899 3323803 MP_OBSID 21921
>>>ERROR: The OBSID change to 21921 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21921:
No ACIS info found for obsid 21921.
This is an HRC-I observation.
2018:295:10:49:50.899 3345305 MP_OBSID 21934
>>>ERROR: The OBSID change to 21934 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21934:
No ACIS info found for obsid 21934.
This is an HRC-I observation.
2018:295:13:42:00.899 3385617 ACISPKT AA00000000
==> ACIS integration time of 33.19 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2018:295:13:45:00.899 3386320 MP_OBSID 48913
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48913:
No ocat info found for obsid 48913
2018:295:13:45:00.899 3386320 ACISPKT AA00000000
2018:295:13:45:04.899 3386335 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:13:46:07.899 3386581 ACISPKT RS_0000001
2018:295:14:19:09.893 3394316 COMMAND_HW CSELFMT2
2018:295:14:19:09.893 3394316 MP_OBSID 21157
==> ObsID change occurs 34.1 minutes after stop science.
LATEST OCAT INFO FOR OBSID 21157:
Target Name: EPIC 210579749 SI Mode: TE_00A5A
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNY NNYYNN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither:
Y Amp: deg Y Freq: deg/sec Y Phase:
Z Amp: deg Z Freq: deg/sec Z Phase:
Cycle: 20 Obj_Flag: NO
2018:295:14:19:09.893 3394316 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2018:295:14:19:09.893 3394316 ACISPKT AA00000000
2018:295:14:19:13.893 3394332 ACISPKT AA00000000
2018:295:14:19:17.893 3394347 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:14:19:41.893 3394441 ACISPKT WSPOW0C80E
==> WSPOW COMMAND LOADS: Feps 1 2 3; I3 S2 S3
2018:295:14:20:44.893 3394687 ACISPKT WT00A5A024
ACIS PBLOCK LOADS:
parameterBlockId = 0x00a5a024
fepCcdSelect = 10 7 6 3 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2018:295:14:20:48.893 3394702 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 21157
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00A5AB is WT00A5A024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,21157,OORMPEN,CSELFMT2,ENAB)
2018:295:14:20:52.893 3394718 ACISPKT RS_0000001
2018:295:14:20:56.893 3394733 ACISPKT RH_0000001
2018:295:14:23:39.293 3395367 SIMFOCUS -418
2018:295:14:25:01.693 3395689 SIMFOCUS -468
2018:295:14:29:40.831 3396778 AOENDITH AOENDITH
==> DITHER ENABLED
2018:295:17:18:22.893 3436279 ACISPKT AA00000000
==> ACIS integration time of 9.50 ks.
This is 95.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2018:295:17:21:22.893 3436981 MP_OBSID 48912
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48912:
No ocat info found for obsid 48912
2018:295:17:21:22.893 3436981 ACISPKT AA00000000
2018:295:17:21:26.893 3436997 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:17:22:29.893 3437243 ACISPKT RS_0000001
2018:295:17:49:31.346 3443570 MP_OBSID 48911
==> ObsID change occurs 28.1 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48911:
No ocat info found for obsid 48911
2018:295:18:20:26.510 3450810 MP_OBSID 48910
LATEST OCAT INFO FOR OBSID 48910:
No ocat info found for obsid 48910
2018:295:18:21:22.893 3451030 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2018:295:18:22:25.893 3451276 ACISPKT RS_0000001
2018:295:18:54:14.538 3458724 MP_OBSID 48909
LATEST OCAT INFO FOR OBSID 48909:
No ocat info found for obsid 48909
2018:295:19:28:11.062 3466672 MP_OBSID 21443
LATEST OCAT INFO FOR OBSID 21443:
Target Name: PS J0147+4630 SI Mode: TE_005C6
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 10 Remaining Exposure time: 10
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYYN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither:
Y Amp: deg Y Freq: deg/sec Y Phase:
Z Amp: deg Z Freq: deg/sec Z Phase:
Cycle: 20 Obj_Flag: NO
2018:295:19:28:11.062 3466672 ACISPKT AA00000000
2018:295:19:28:15.062 3466687 ACISPKT AA00000000
2018:295:19:28:19.062 3466703 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:19:28:43.062 3466797 ACISPKT WSPOW1C00E
==> WSPOW COMMAND LOADS: Feps 1 2 3; S2 S3 S4
2018:295:19:29:46.062 3467042 ACISPKT WT005C6024
ACIS PBLOCK LOADS:
parameterBlockId = 0x005c6024
fepCcdSelect = 10 7 6 8 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2018:295:19:29:50.062 3467058 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 21443
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_005C6B is WT005C6024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,21443,OORMPEN,CSELFMT2,ENAB)
2018:295:19:29:54.062 3467074 ACISPKT RS_0000001
2018:295:19:29:58.062 3467089 ACISPKT RH_0000001
2018:295:22:44:52.456 3512726 ACISPKT AA00000000
==> ACIS integration time of 10.55 ks.
This is 105.48% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2018:295:22:44:52.456 3512726 SIMTRANS -99616 (HRC-S)
2018:295:22:47:52.456 3513428 ACISPKT AA00000000
2018:295:22:47:52.456 3513428 MP_OBSID 48908
==> ObsID change occurs 0.0 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 48908:
No ocat info found for obsid 48908
2018:295:22:47:56.456 3513444 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:22:48:59.456 3513690 ACISPKT RS_0000001
2018:295:22:50:29.856 3514043 COMMAND_SW OORMPDS
==>The requested SI_MODE for the inbound CTI is TE_00CA8
2018:295:22:50:29.856 3514043 ACISPKT AA00000000
2018:295:22:50:33.856 3514058 ACISPKT AA00000000
2018:295:22:50:37.856 3514074 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:295:22:51:01.856 3514167 ACISPKT WSPOW3E03E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4 5; S1 S2 S3 S4 S5
2018:295:22:52:04.856 3514413 ACISPKT WBTX_QUIET
2018:295:22:52:08.856 3514429 ACISPKT WT00CA8014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00ca8014
fepCcdSelect = 10 7 5 6 9 8
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 65535
2018:295:22:52:12.856 3514445 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 48908
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00CA8B is WT00CA8014 and is stored.
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,48908,OORMPDS,CSELFMT2,ENAB)
2018:295:22:52:16.856 3514460 ACISPKT RS_0000001
2018:295:22:52:20.856 3514476 ACISPKT RH_0000001
2018:295:22:52:43.856 3514566 ACISPKT RBTXINGALL
2018:296:01:28:14.856 3550979 ACISPKT AA00000000
==> ACIS integration time of 7.96 ks.
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
2018:296:01:30:11.885 3551436 MP_OBSID 48907
==> ObsID change occurs 2.0 minutes after stop science.
>>>ERROR: ObsID change occurs less than 3 minutes after a stop science command.
LATEST OCAT INFO FOR OBSID 48907:
No ocat info found for obsid 48907
2018:296:01:31:14.596 3551488 ORBPOINT EEF1000
==> Entry leg pad time is 9.64 ks.
AE-8 EVENTS TIME CHECK:
from backstop: EE1RADZ0 = 296:01:31:14
from CRM file: EE1RADZ0 = 296:01:31:14
==> CRM Pad Time: 9.645 ks and Backstop Pad Time: 9.64 ks agree.
2018:296:01:31:14.856 3551682 ACISPKT AA00000000
2018:296:01:31:23.856 3551717 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:296:01:32:26.856 3551963 ACISPKT RS_0000001
2018:296:01:55:21.885 3557329 MP_OBSID 48906
==> ObsID change occurs 24.1 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48906:
No ocat info found for obsid 48906
2018:296:02:31:14.856 3565730 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2018:296:02:32:17.856 3565976 ACISPKT RS_0000001
2018:296:05:19:29.142 3565976 ORBPOINT EPERIGEE
>>>ERROR: Time delta between EE1RADZ0/EEF1000 and EPERIGEE is less than 4.0 hrs.
>>>ERROR: Time delta between the last WSVIDALLDN and the 2nd last AA00000000 is greater than 10.0 mins!
2018:296:11:34:53.349 3693022 MP_OBSID 48905
LATEST OCAT INFO FOR OBSID 48905:
No ocat info found for obsid 48905
2018:296:11:51:14.596 3696851 ACISPKT AA00000000
2018:296:11:51:14.596 3696851 ORBPOINT XEF1000
==> The requested SI_MODE for the outbound CTI is TE_007AE
2018:296:11:51:18.596 3696867 ACISPKT AA00000000
2018:296:11:51:22.596 3696883 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:296:11:51:46.596 3696976 ACISPKT WSPOW3F03F
==> WSPOW COMMAND LOADS: All Feps; std S array
2018:296:11:52:49.596 3697222 ACISPKT WBTX_QUIET
2018:296:11:52:53.596 3697238 ACISPKT WT007AE024
ACIS PBLOCK LOADS:
parameterBlockId = 0x007ae024
fepCcdSelect = 9 7 5 6 4 8
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 32
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3750
windowSlotIndex = 65535
2018:296:11:52:57.596 3697253 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 48905
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_007AEB is WT007AE024 and is stored.
====> CHANDRA STATUS ARRAY=(HRC-S,HETG-OUT,LETG-OUT,48905,OORMPDS,CSELFMT2,ENAB)
2018:296:11:53:01.596 3697269 ACISPKT RS_0000001
2018:296:11:53:05.596 3697284 ACISPKT RH_0000001
2018:296:11:53:28.596 3697374 ACISPKT RBTXINGALL
2018:296:12:06:45.347 3700484 MP_OBSID 48904
==> ObsID change occurs 15.4 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48904:
No ocat info found for obsid 48904
2018:296:12:40:22.691 3708356 MP_OBSID 48903
LATEST OCAT INFO FOR OBSID 48903:
No ocat info found for obsid 48903
2018:296:13:12:35.996 3715901 MP_OBSID 48902
LATEST OCAT INFO FOR OBSID 48902:
No ocat info found for obsid 48902
2018:296:13:45:59.410 3723719 MP_OBSID 48901
LATEST OCAT INFO FOR OBSID 48901:
No ocat info found for obsid 48901
2018:296:14:34:54.596 3735173 ACISPKT AA00000000
==> ACIS integration time of 8.32 ks.
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI-CTI
2018:296:14:37:53.596 3735872 COMMAND_SW OORMPEN
==> Exit leg pad time is 10.00 ks.
AE-8 EVENTS TIME CHECK:
from backstop: XE1RADZ0 = 296:11:51:14
from CRM file: XE1RADZ0 = 296:11:51:14
==> CRM Pad Time: 10 ks and Backstop Pad Time: 10.00 ks agree.
2018:296:14:37:54.596 3735876 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2018:296:14:37:55.596 3735880 MP_OBSID 21510
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 21510:
Target Name: IRAS 04416+1215 SI Mode: TE_00C2C
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 3.6 Remaining Exposure time: 3.6
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: F Frame Time:
Chips Turned On: NNNN NNYYYN
Subarray Type: CUSTOM Start: 449 Rows: 128 Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither:
Y Amp: deg Y Freq: deg/sec Y Phase:
Z Amp: deg Z Freq: deg/sec Z Phase:
Cycle: 20 Obj_Flag: NO
2018:296:14:37:55.596 3735880 ACISPKT AA00000000
2018:296:14:37:59.596 3735895 ACISPKT AA00000000
2018:296:14:38:03.596 3735911 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:296:14:38:27.596 3736004 ACISPKT WSPOW1C00E
==> WSPOW COMMAND LOADS: Feps 1 2 3; S2 S3 S4
2018:296:14:39:30.596 3736250 ACISPKT WT00C2C014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00c2c014
fepCcdSelect = 10 7 6 8 10 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 448
subarrayRowCount = 127
primaryExposure = 6
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2018:296:14:39:34.596 3736266 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 21510
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_00C2CB is WT00C2C014 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,21510,OORMPEN,CSELFMT2,ENAB)
2018:296:14:39:38.596 3736282 ACISPKT RS_0000001
2018:296:14:39:42.596 3736297 ACISPKT RH_0000001
2018:296:15:53:08.596 3753491 ACISPKT AA00000000
==> ACIS integration time of 3.60 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2018:296:15:56:08.596 3754194 MP_OBSID 48900
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48900:
No ocat info found for obsid 48900
2018:296:15:56:08.596 3754194 ACISPKT AA00000000
2018:296:15:56:12.596 3754209 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:296:15:57:15.596 3754455 ACISPKT RS_0000001
2018:296:16:25:28.610 3761062 COMMAND_HW CSELFMT1
2018:296:16:25:28.610 3761062 MP_OBSID 21935
==> ObsID change occurs 29.3 minutes after stop science.
LATEST OCAT INFO FOR OBSID 21935:
No ACIS info found for obsid 21935.
This is an HRC-I observation.
2018:296:16:25:28.610 3761062 SIMTRANS -50504 (HRC-I)
2018:296:16:29:58.010 3762113 SIMFOCUS -716
2018:296:16:30:41.303 3762282 ACISPKT WSVIDALLDN
2018:296:16:30:59.303 3762353 ACISPKT WSPOW08E1E
==> WSPOW COMMAND LOADS: Feps 1 2 3 4; I1 I2 I3 S3
2018:296:16:32:02.303 3762598 ACISPKT RS_0000001
2018:296:16:32:06.303 3762614 ACISPKT RH_0000001
2018:296:16:32:29.303 3762704 ACISPKT WT00D06014
ACIS PBLOCK LOADS:
parameterBlockId = 0x00d06014
fepCcdSelect = 10 7 1 2 3 10
fepMode = 2 # FEP_TE_MODE_EV3x3
bepPackingMode = 3 # BEP_TE_MODE_EVHIST
recomputeBias = 1
trickleBias = 0
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 33
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 0
eventAmplitudeRange = 65535
windowSlotIndex = 65535
2018:296:16:32:33.303 3762719 ACISPKT XTZ0000005
====> CHANDRA STATUS ARRAY=(HRC-I,HETG-OUT,LETG-OUT,21935,OORMPEN,CSELFMT1,ENAB)
2018:296:16:36:30.303 3763644 AOENDITH AOENDITH
==> DITHER ENABLED
2018:296:19:29:40.303 3804191 MP_OBSID 21936
>>>ERROR: The OBSID change to 21936 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21936:
No ACIS info found for obsid 21936.
This is an HRC-I observation.
2018:296:19:54:50.303 3810083 MP_OBSID 21937
>>>ERROR: The OBSID change to 21937 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21937:
No ACIS info found for obsid 21937.
This is an HRC-I observation.
2018:296:20:20:00.303 3815976 MP_OBSID 21938
>>>ERROR: The OBSID change to 21938 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21938:
No ACIS info found for obsid 21938.
This is an HRC-I observation.
2018:296:20:45:10.303 3821869 MP_OBSID 21939
>>>ERROR: The OBSID change to 21939 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21939:
No ACIS info found for obsid 21939.
This is an HRC-I observation.
2018:296:21:10:20.303 3827761 MP_OBSID 21940
>>>ERROR: The OBSID change to 21940 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21940:
No ACIS info found for obsid 21940.
This is an HRC-I observation.
2018:296:22:42:10.303 3849264 MP_OBSID 21941
>>>ERROR: The OBSID change to 21941 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21941:
No ACIS info found for obsid 21941.
This is an HRC-I observation.
2018:296:23:07:20.303 3855157 MP_OBSID 21942
>>>ERROR: The OBSID change to 21942 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21942:
No ACIS info found for obsid 21942.
This is an HRC-I observation.
2018:296:23:32:30.303 3861049 MP_OBSID 21943
>>>ERROR: The OBSID change to 21943 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21943:
No ACIS info found for obsid 21943.
This is an HRC-I observation.
2018:296:23:57:40.303 3866942 MP_OBSID 21944
>>>ERROR: The OBSID change to 21944 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21944:
No ACIS info found for obsid 21944.
This is an HRC-I observation.
2018:297:00:22:50.303 3872835 MP_OBSID 21945
>>>ERROR: The OBSID change to 21945 occurs more than 5 mins after a start science.
LATEST OCAT INFO FOR OBSID 21945:
No ACIS info found for obsid 21945.
This is an HRC-I observation.
2018:297:01:51:40.303 3893635 ACISPKT AA00000000
==> ACIS integration time of 22.68 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
2018:297:01:54:40.303 3894337 MP_OBSID 48899
==> ObsID change occurs 3.0 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48899:
No ocat info found for obsid 48899
2018:297:01:54:40.303 3894337 ACISPKT AA00000000
2018:297:01:54:44.303 3894353 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:297:01:55:47.303 3894598 ACISPKT RS_0000001
2018:297:02:28:50.437 3902338 MP_OBSID 48898
==> ObsID change occurs 34.2 minutes after stop science.
LATEST OCAT INFO FOR OBSID 48898:
No ocat info found for obsid 48898
2018:297:02:54:40.303 3908386 ACISPKT WSPOW0002A
==> WSPOW COMMAND LOADS: Feps 1 3 5; All vids down
2018:297:02:55:43.303 3908632 ACISPKT RS_0000001
2018:297:03:00:15.214 3909693 COMMAND_HW CSELFMT2
2018:297:03:00:15.214 3909693 MP_OBSID 21468
LATEST OCAT INFO FOR OBSID 21468:
Target Name: ESO359-G029 SI Mode: TE_005C6
Instrument: ACIS-S Grating: NONE Type: GO
Exposure Time: 3 Remaining Exposure time: 3
Offset: Y: 0 Z: 0 Z-sim:
ACIS Exposure Mode: TE Event TM Format: VF Frame Time:
Chips Turned On: NNNN NNYYYN
Subarray Type: NONE Start: Rows: Frame Time:
Duty Cycle: N Number: Tprimary: Tsecondary:
Onchip Summing: N Rows: 1 Columns: 1
Event Filter: N Lower: Range:
Window Filter: N Start Row: Start Column:
Height: Width:
Lower Energy: Energy Range: Sample Rate:
Dither:
Y Amp: deg Y Freq: deg/sec Y Phase:
Z Amp: deg Z Freq: deg/sec Z Phase:
Cycle: 20 Obj_Flag: NO
2018:297:03:00:15.214 3909693 SIMTRANS 75624 (ACIS-S)
==> THERE IS A Z-SIM OF 0.00 mm FOR THIS OBSERVATION.
2018:297:03:00:15.214 3909693 ACISPKT AA00000000
2018:297:03:00:19.214 3909708 ACISPKT AA00000000
2018:297:03:00:23.214 3909724 ACISPKT WSPOW00000
==> WSPOW COMMAND LOADS: All Feps down; All vids down
2018:297:03:00:47.214 3909818 ACISPKT WSPOW1C00E
==> WSPOW COMMAND LOADS: Feps 1 2 3; S2 S3 S4
2018:297:03:01:50.214 3910063 ACISPKT WT005C6024
ACIS PBLOCK LOADS:
parameterBlockId = 0x005c6024
fepCcdSelect = 10 7 6 8 10 10
fepMode = 3 # FEP_TE_MODE_EV5x5
bepPackingMode = 0 # BEP_TE_MODE_FAINT
recomputeBias = 1
trickleBias = 1
subarrayStartRow = 0
subarrayRowCount = 1023
primaryExposure = 31
secondaryExposure = 0
dutyCycle = 0
lowerEventAmplitude = 20
eventAmplitudeRange = 3250
windowSlotIndex = 65535
2018:297:03:01:54.214 3910079 ACISPKT XTZ0000005
---------------------------------------------------------------------------
Parameter block and set up check for 21468
---------------------------------------------------------------------------
==> Parameter Block for SI mode TE_005C6B is WT005C6024 and is stored.
==> FP instrument, Grating and SIM-Z offsets OK.
==> Parameter Block and OCAT are consistent for this observation
====> CHANDRA STATUS ARRAY=(ACIS-S,HETG-OUT,LETG-OUT,21468,OORMPEN,CSELFMT2,ENAB)
2018:297:03:01:58.214 3910095 ACISPKT RS_0000001
2018:297:03:02:02.214 3910110 ACISPKT RH_0000001
2018:297:03:04:44.614 3910744 SIMFOCUS -418
2018:297:03:06:07.014 3911066 SIMFOCUS -468
2018:297:03:10:09.420 3912012 AOENDITH AOENDITH
==> DITHER ENABLED
2018:297:04:11:08.214 3926290 ACISPKT AA00000000
==> ACIS integration time of 3.00 ks.
This is 100.00% of the requested time.
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@-@
-- CHANDRA LOAD END --
************************
ACIS LOAD REVIEW SUMMARY
************************
THERE ARE 0 REAL-TIME COMM PASSAGES IN THIS LOAD.
FREQUENCY OF ACIS COMMAND OCCURRENCES TABLE:
----------------------------------------------------------------------
OBSIDs WSVIDALLDNs RS_0000001 RH_0000001 X[TC]Z0000005 AA00000000
----------------------------------------------------------------------
48 6 20 8 8 29
**NOTE: There are 1 perigee crossings in this load.
FREQUENCY OF OTG INSERTIONS/RETRACTIONS:
--------------------------------------------
LETG_INs LETG_REs HETG_INs HETG_REs
--------------------------------------------
0 0 0 0
--------------------------------------------------------------------------
--------------------------------------------------------------------------
--------------------------------------------------------------------------
AT LEAST ONE INSTANCE OF THE FOLLOWING TYPES OF WARNINGS OR ERRORS WERE ENCOUNTERED:
o. Either Radmon was NOT ENABLED at least 15 ks after an electron 1 exit.
-OR- Radmon was NOT enabled after electron 1 exit.
o. The OBSID change to 48918 that occurs less than 3 mins after a stop science.
o. The OBSID change to 21912 occurs more than 5 mins after a start science.
o. The OBSID change to 21913 occurs more than 5 mins after a start science.
o. The OBSID change to 21914 occurs more than 5 mins after a start science.
o. The OBSID change to 21915 occurs more than 5 mins after a start science.
o. The OBSID change to 21916 occurs more than 5 mins after a start science.
o. The OBSID change to 21917 occurs more than 5 mins after a start science.
o. The OBSID change to 21918 occurs more than 5 mins after a start science.
o. The OBSID change to 21919 occurs more than 5 mins after a start science.
o. The OBSID change to 21920 occurs more than 5 mins after a start science.
o. The OBSID change to 21921 occurs more than 5 mins after a start science.
o. The OBSID change to 21934 occurs more than 5 mins after a start science.
o. The OBSID change to 48908 that occurs less than 3 mins after a stop science.
o. The OBSID change to 48907 that occurs less than 3 mins after a stop science.
o. Time difference between a WSVIDALLDN command and the 2nd AA00000000 that precedes it is greater than 10 mins.
o. The OBSID change to 21936 occurs more than 5 mins after a start science.
o. The OBSID change to 21937 occurs more than 5 mins after a start science.
o. The OBSID change to 21938 occurs more than 5 mins after a start science.
o. The OBSID change to 21939 occurs more than 5 mins after a start science.
o. The OBSID change to 21940 occurs more than 5 mins after a start science.
o. The OBSID change to 21941 occurs more than 5 mins after a start science.
o. The OBSID change to 21942 occurs more than 5 mins after a start science.
o. The OBSID change to 21943 occurs more than 5 mins after a start science.
o. The OBSID change to 21944 occurs more than 5 mins after a start science.
o. The OBSID change to 21945 occurs more than 5 mins after a start science.
--------------------------------------------------------------------------
ACIS LOAD REVIEW FAILED