The present targets for the Total and Cold times are:
I3 :130ks
S3 :170ks
....to be achieved by acquiring time as equally as possible amongst the three SI Modes: (TE_007AC, TE_007AE, & TE_00B26).
Total Cold Time on I3: 99136 seconds
Total Cold Time on S3: 131235 seconds
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Exp. Cold Time (secs) | 158079 | 158079 | 158079 |
Total Actual Cold Time (secs) | 20504 | 32099 | 78632 |
Delta From Expected (secs) | -137574 | -125979 | -79446 |
% of Exp. Cold Total (secs) | 12.97% | 20.31% | 49.74% |
Stats | TE_007AC | TE_007AE | TE_00B26 |
---|---|---|---|
Total Expected Time (secs) | 263466 | 263466 | 263466 |
Total Actual Time (secs) | 243270 | 226447 | 398285 |
Delta From Expected (secs) | -20196 | -37019 | 134819 |
% of Expected Total (secs) | 92.33% | 85.95% | 151.17% |
SI Mode | Total Number of Obs. | Total Exposure Time (sec) | Average Exposure (sec/obs) |
---|---|---|---|
Primary 6 Chip SI Modes | |||
TE_007AC | 33 | 243270.00 | 7371.82 |
TE_007AE | 30 | 207013.00 | 6900.43 |
TE_00B26 | 23 | 161325.00 | 7014.13 |
Old 6 Chip SI Modes | |||
TE_00216 | 0 | 0.00 | 0.00 |
TE_0021C | 0 | 0.00 | 0.00 |
TE_008EA | 0 | 0.00 | 0.00 |
5 Chip SI Modes | |||
TE_00C60 | 9 | 85690.00 | 9521.11 |
TE_00CA8 | 2 | 19434.00 | 9717.00 |
4 Chip SI Modes | |||
TE_00C62 | 7 | 151270.00 | 21610.00 |
Totals: | 104 | 868002.00 | 8346.17 |
Rule #1: The key time period for balancing SI mode statistics is the 6 month Epoch By the end of the epoch, the SI mode statistics should match the rules stated below. Rule #2: Each of the three, default, 6 chip, SI modes (or their 5 chip equivalents) must be used at least once in each load week. - If two SI modes are lagging in either cold time or total time, apportion the week's ECS measurements between the two of them roughly commensurate with the amount they are lagging. - The 6 month Epoch allows "even" correction of two lagging SI modes. No need to pile a weeks worth of ECS measurements on one SI mode if two are lagging. Rule #3: Make certain to spread the amount of COLD ECS time as evenly as possible across all three SI modes Balance Cold measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis
Rule #4: Spread the amount of *Total* ECS time as evenly as possible across all three SI modes.
- Balance Total measurement data between the three default 6-chip modes within 10% of each other on an Epoch basis.
Rule #3 takes precedence over Rule #4.
Rule #5:At least 60% of scheduled ECS measurement time must be -119.2 deg. C
Rule #6: Any ECS measurements during a Perigee Passage that are cold MUST be assigned to the nominal ECS run SI modes. i.e. Any requested Rawmode runs can be done with a warm focal plane.
All of the TE_00CA8s get counted as TE_007AE
Half of the TE_00C60s get counted towards TE_007AC and the other half get counted with the TE_00B26s
Half of the TE_00C62s get counted towards TE_007AC and the other half get counted with the TE_00B26s.
So watchout for TE_00B26 over-representation.