Table 12: The power law fit coeffcients for parallel CTI in w134c4r. The model reads as: p_cti = a + d * ADU ^ b
node | a | b | d |
---|---|---|---|
0 | -4.87654E-06 | -0.584979 | 1.46739E-03 |
1 | -5.27427E-06 | -0.657534 | 1.65760E-03 |
2 | -5.49702E-06 | -0.628394 | 1.24954E-03 |
3 | -5.56805E-06 | -0.601623 | 1.79695E-03 |