About Chandra Archive Proposer Instruments & Calibration Newsletters Data Analysis HelpDesk Calibration Database NASA Archives & Centers Chandra Science Links

Skip the navigation links
Last modified: 27 September 2006

URL: http://cxc.harvard.edu/ciao3.4/caveats/theta.html
Hardcopy (PDF): A4 | Letter

Caveat Regarding Off-axis Angle Theta and Phi

Return to: Data Caveats Index

All event files processed using a standard data processing version prior to DS6.9 (released on 10 August 2002, please see release notes for DS6.9) have the off-axis angle THETA and rotation angle (azimuth) PHI values switched. This occurs in both ACIS and HRC data. Using dmcoords to find the off-axis angle of your source yields correct results, no matter what processing version was used on your data. However tools such as dmstat when used with data processed before DS6.9 will give results with THETA and PHI switched.

Please see our thread A Note on Processing Versions for instructions on how to check which processing version was used on your data.

Hardcopy (PDF): A4 | Letter
Last modified: 27 September 2006


The Chandra X-Ray Center (CXC) is operated for NASA by the Smithsonian Astrophysical Observatory.
60 Garden Street, Cambridge, MA 02138 USA.    Email: cxcweb@head.cfa.harvard.edu