Version $Revision: 1.3 $
Last Update $Date: 2001/11/08 14:46:10 $
HRC CCB Status not reviewed

AXAF Constraints, Restrictions, & Limitations

Number: HRC-C-007

Type: Constraint

Original Date: 1/31/97


Subsystem: HRC

Subject: HRC High Voltage and Electronic Calibration Mode

Source: Informal CARD inputs, e-mail, M. Juda, 1/28/97


CRL Statement:

HRC high voltages must be commanded OFF prior to turning ON the internal electrical calibration mode.


CRL Rationale/Justification:

HRC sensitivity to high voltage when entering the calibration mode is derived from the HRC design.


CRL Impact:

HRC high voltage switching transients will damage the HRC preamplifier inputs.


Recommended Action:

Incorporate into the Systems and Operations Procedures, with ASC providing the inputs.