File $Source: /home/juda/www/hrc_flight/contingency/RCS/mcp_off.html,v $
Version $Revision: 1.2 $
Last Update $Date: 1999/03/03 21:56:48 $
HRC CCB Status Approved

OP03 Procedures op03:

HRC Contingency Procedures

Excessive HRC MCP Rates - HRC MCP HV Off

Description:

This procedure turns off the MCP HV to protect them in the event of excessive rates.

Procedure Trigger:

The procedure shall be initiated by the Flight Operations Team if any MCP event rate telemetry exceeds the "red" limit for more than 5 seconds in format 1 or for more than 40 seconds in any other format. The MCP rate telemetry mnemonics for these rates are: Note: Telemetry mnemonics 2TLEV2RT and 2VLEV2RT are not included because experience gained during the ground test program showed they can occasionally indicate a red-limit condition when none exists.

This procedure shall also be executed by the Flight Operations Team at any time at the request of the Science Operations Team.

Procedure


$Log: mcp_off.html,v $

Revision 1.2 1999/03/03 21:56:48 juda

approved

Revision 1.1 1998/11/04 13:59:59 juda

Initial revision


Dr. Michael Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356