File | $Source: /home/juda/www/hrc_flight/RCS/fmt3.html,v $ |
Version | $Revision: 1.4 $ |
Last Update | $Date: 1999/05/10 18:08:08 $ |
HRC CCB Status | Approved |
OP03 Procedures | op03: |
The serial digital command to the HRC to switch the synchronization signal is sent first; followed by the command to the CTU to change formats. Serial digital commands to the HRC to reset and then re-enable the serial digital telemetry FIFOs are then issued; this flushes the buffers and restarts them.
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
00:00:01.000 | 2NXILASL | Select timing for HRC next-in-line mode telemetry | 2OBNLASL | NEXT | sd1a01 | ||
00:00:00.500 | CSELFMT3 | CTU telemetry mode select format 3 | CCSDSTMF | FMT3 | |||
00:00:01.000 | 2FIFOAOF | Reset event data fifo | 2FIFOAVR | RSET | sd4500 | ||
00:00:01.000 | 2FIFOAON | Enable event data FIFO | 2FIFOAVR | ENAB | sd4501 |
$Log: fmt3.html,v $
Revision 1.4 1999/05/10 18:08:08 jhc
corrected initial time delay to 1 sec
Revision 1.3 1998/09/14 19:58:46 juda
Marked as Approved - changed "Caution" of 1 major frame to synch to as many as 3 - minor grammar corrections to description section.
Revision 1.2 1998/06/08 17:53:35 juda
corrected spelling error "Rest" to "Reset"
Revision 1.1 1998/05/11 20:23:07 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu