File $Source: /home/juda/www/hrc_flight/RCS/i_mcp_hv_on.html,v $
Version $Revision: 1.6 $
Last Update $Date: 1999/05/10 18:08:08 $
HRC CCB Status Approved

OP03 Procedures op03:

HRC Command Sequences

HRC-I MCP HV On - SCS #92

Description:

This sequence is used to turn on the HRC-I MCP HV power supply. This sequence disables the current limiter, sets the HV command levels to zero (first top then bottom), turns the HRC-I MCP HVPS on, and finally re-enables the current limiter.

Cautions/Restrictions:

This command sequence should only be used if the following conditions are met:
  1. The HRC-S MCP HVPS must be off
  2. The HRC is configured to be using the HRC-I with "Set HRC-I Unique Defaults"

Delta-Time Command Mnemonic Description Cmd Field Mnemonic Data Parameter Telemetry Verifier Expected Value Notes
00:00:01.000 2IMCLDS Imaging HVPS current limit disable     2IMCLST DISA sd0c00
00:00:01.000 2IMTTHV Set imaging top MCP HV step to 0 2IMTTHV2 0 2IMTPAST 0 sd0a00
00:00:01.000 2IMTBHV Set imaging bottom MCP HV step to 0 2IMTBHV2 0 2IMBPAST 0 sd0b00
00:00:01.000 2IMHVON Imaging MCP HVPS On     2IMONST ON sd0901
00:00:02.000 2IMCLEN Imaging HVPS current limit enable     2IMCLST ENAB sd0c01


$Log: i_mcp_hv_on.html,v $

Revision 1.6 1999/05/10 18:08:08 jhc

corrected initial time delay to 1 sec

Revision 1.5 1999/03/03 20:31:38 juda

changed link for "Set HRC-I Unique Defaults" since filename has changed

Revision 1.4 1998/05/18 15:46:18 juda

corrected telemetry verifier mnemonics for MCP HV Step commands (2IMTPST -> 2IMTPAST and 2IMBPST -> 2IMBPAST)

Revision 1.3 1998/05/12 19:55:14 juda

Added SCS # (assigned by TRW)

Revision 1.2 1998/05/08 20:00:56 juda

Marked as "Approved"

Revision 1.1 1998/05/07 17:39:13 juda

Initial revision


Dr. Michael Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356