Radiation Zone Entry
Description:
This sequence is to prepare the HRC for radiation zone entry. The MCP
HV of the active detector is lowered to half of its operational level
and the command sequence to raise the HV is disabled. The dither
control command sequence is terminated. The antico shield PMT HVPS are
turned off and their commanded output steps set to zero. Finally, if
the HRC detector housing door is open it is moved to the "mostly"
closed position, making sure that the shutters are "homed" first.
Cautions/Restrictions:
None
Procedure
- If HRC-I is the current detector in use
- Else HRC-S is the current detector in use
- Terminate SCS #91 - HRC Dither Control
- If HRC detector housing door is OPEN