OP03 Procedures op03:

HRC Higher-Level Sequences

-Y Shutter Scan

Description:

This sequence is used to scan the -Y shutter across the aim-point on one of the HRC detectors. After verifying that the door is not in the way of the shutter travel, the -Y shutter is moved to an initial starting position, POS_START. Then, for a specified number of steps (NUM_STEPS), the shutter is moved STEP_SIZE motor steps toward the maximum limit switch. At each shutter position there is a pause of DWELL_TIME to collect data.

Cautions/Restrictions:

The HRC Door must be out of the way of the shutter travel, either the door must be closed or it must be fully open (see HRC-C-008). This is accomplished in the first sequence in the procedure.

Flow Diagram

Procedure


$Log: scan_negy.html,v $

Revision 1.2 1999/04/21 20:10:13 juda

Added comment to constraint about door position being handled by the initial sequence. Removed the initial verification step.

Marked as Approved

Revision 1.1 1999/03/03 21:37:33 juda

Initial revision

Revision 1.1 1998/10/14 14:31:15 juda

Initial revision