File | $Source: /home/juda/www/hrc_flight/RCS/s_unique.html,v $ |
Version | $Revision: 1.2 $ |
Last Update | $Date: 1999/05/10 18:08:08 $ |
HRC CCB Status | Approved |
OP03 Procedures | op03: |
This sequence should not be executed until the HRC has been powered for at least 90 sec.
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
00:00:01.000 | 2PRASSL | HRC-S select to use CEA A pre-amplifiers | 2PREADS | SPEC | hlp39 | ||
00:00:01.000 | 2PRBISL | HRC-I select to use CEA B pre-amplifiers | 2PREBDS | IMAG | hlp7b | ||
00:00:02.000 | 2PSHBALD | Load High-byte motor control position word | 2PSHBAL1 | 0 | 2SCTHAST | 0 | sd1800 |
00:00:01.000 | 2PSLBALD | Load Low-byte motor control position word | 2PSLBAL1 | 0 | 2SCTHAST | 0 | sd1900 |
00:00:01.000 | 2SPNLASL | Select normal mode for HRC-S | 2SPMDASL | NORM | sd1b01 | ||
00:00:01.000 | 2CALBAAM | Set calibration pulse amplitude to 0 | 2CALBAA1 | 0 | 2CALPALV | 0 | sd2000 |
00:00:01.000 | 2CLMDAOF | Set calibration mode to off | 2CLMDAST | OFF | sd2100 | ||
00:00:01.000 | 2FCPUALV | Set forced coarse U-axis position to 0 | 2FCPUAL1 | 0 | 2FCPUAST | 0 | sd2200 |
00:00:01.000 | 2FCPVALV | Set forced coarse V-axis position to 0 | 2FCPVAL1 | 0 | 2FCPVAST | 0 | sd2300 |
00:00:01.000 | 2CBHUALV | Set center-blank region U-axis upper limit to 74 | 2CBHUAL1 | 74 | 2CBHUAST | 74 | sd244a
Normal LETG strip |
00:00:01.000 | 2CBLUALV | Set center-blank region U-axis lower limit to 69 | 2CBLUAL1 | 69 | 2CBLUAST | 69 | sd2545
Normal LETG strip |
00:00:01.000 | 2CBHVALV | Set center-blank region V-axis upper limit to 255 | 2CBHVAL1 | 255 | 2CBHVAST | 255 | sd26ff
changed from EGSE script - 255 is max possible value |
00:00:01.000 | 2CBLVALV | Set center-blank region V-axis lower limit to 0 | 2CBLVAL1 | 0 | 2CBLVAST | 0 | sd2700
changed from EGSE script - 0 is min possible value |
00:00:01.000 | 2ULDIATH | Set upper level veto threshold to 255 | 2ULDIAT1 | 255 | 2ULDIALV | 255 | sd28ff |
00:00:01.000 | 2LLDIATH | Set trigger level threshold to 8 | 2LLDIAT1 | 8 | 2LLDIALV | 8 | sd2908 |
00:00:01.000 | 2GRDVAAM | Set grid bias level to step 46 dec [2e hex] | 2GRDVAA1 | 46 | 2GRDVALV | 46 | sd2b2e |
00:00:01.000 | 2WDTHATH | Set coarse width veto threshold to 3 | 2WDTHAT1 | 3 | 2WDTHAST | 3 | sd2c03 |
00:00:01.000 | 2RSRFAAM | Set ADC range switch setting to 125 dec [7d hex] | 2RSRFAA1 | 125 | 2RSRFALV | 125 | sd2d7d |
00:00:01.000 | 2SHL1ADI | Disable anticoincidence shield veto | 2SHLDAVR | DISA | sd4000 | ||
00:00:01.000 | 2WDTHADI | Disable width veto | 2WDTHAVR | DISA | sd4100 | ||
00:00:01.000 | 2ULDIADI | Disable upper level discr. veto | 2ULDIAVR | DISA | sd4200 | ||
00:00:01.000 | 2CBLKADI | Disable center-blank function | 2CBLKAVR | DISA | sd4300 | ||
00:00:01.000 | 2EBLKAEN | Enable edge-blank function | 2EBLKAVR | ENAB | sd4401 | ||
00:00:01.000 | 2SMOIAEN | Enable over-current protection for selected motor | 2DROIAST | ENAB | sd4901 | ||
00:00:01.000 | 2SMOTAEN | Enable over-temperature protection for selected motor | 2DROTAST | ENAB | sd4a01 | ||
00:00:01.000 | 2CHPLAEN | Enable primary closed/home limit switch | 2CPLSAST | ENAB | sd5001 | ||
00:00:01.000 | 2CHSLAEN | Enable secondary closed/home limit switch | 2CSLSAST | ENAB | sd5101 | ||
00:00:01.000 | 2OMPLAEN | Enable primary open/maximum limit switch | 2OPLSAST | ENAB | sd5201 | ||
00:00:01.000 | 2OMSLAEN | Enable secondary open/maximum limit switch | 2OSLSAST | ENAB | sd5301 | ||
00:00:01.000 | 2STFLAEN | Enable motor stop flags | 2SFLGAST | ENAB | sd5401 | ||
00:00:01.000 | 2FIFOAOF | Reset event data fifo | 2FIFOAVR | RSET | sd4500 | ||
00:00:01.000 | 2FIFOAON | Enable event data FIFO | 2FIFOAVR | ENAB | sd4501 |
$Log: s_unique.html,v $
Revision 1.2 1999/05/10 18:08:08 jhc
corrected initial time delay to 1 sec
Revision 1.1 1999/03/03 20:12:23 juda
Initial revision
Revision 1.5 1998/06/01 12:21:00 juda
Corrected 2SMOTAEN serial digital value (changed sd4a00 to sd4a01)
Revision 1.4 1998/05/13 16:28:05 juda
Added "File" entry to version table
Revision 1.3 1998/05/06 20:19:10 juda
Changed "side" references to "CEA" - removed command to set "OBSV" telemetry timing - marked as approved
Revision 1.2 1998/05/05 16:55:57 juda
expanded the list of serial digital commands that are sent after the high-level pulse commands to select the preamps - solves problem of high-level pulse causing value changes
Revision 1.1 1998/04/29 19:25:58 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu