| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.418 | 0.021 | (2.12+/-0.02)e2 | (1.13+/-0.96)e2 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.386 | 0.020 | (2.13+/-0.02)e2 | 55.91 +/- 97.58 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.158 | 0.042 | (1.53+/-0.04)e2 | (3.92+/-2.18)e2 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -0.222 | 0.230 | (6.76+/-0.21)e2 | (2.17+/-1.10)e-7 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.989 | 0.039 | (2.64+/-0.04)e2 | 13.81 +/- 133.59 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.435 | 0.067 | (2.90+/-0.06)e2 | (3.76+/-4.48)e2 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.278 | 0.073 | (2.89+/-0.07)e2 | 0.54 +/- 507.33 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.284 | 0.071 | (2.92+/-0.07)e2 | -(2.90+/-4.80)e2 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.664 | 0.025 | (2.50+/-0.03)e2 | -61.42 +/- 81.76 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.669 | 0.024 | (2.46+/-0.03)e2 | (1.60+/-0.75)e2 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 1.916 | 0.052 | (3.09+/-0.06)e2 | 47.36 +/- 200.57 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 1.895 | 0.052 | (3.03+/-0.06)e2 | -16.80 +/- 207.06 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -1.589 | 0.080 | (3.42+/-0.08)e2 | -(2.25+/-4.55)e2 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.243 | 0.022 | (1.94+/-0.02)e2 | (1.61+/-1.35)e2 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.255 | 0.023 | (1.94+/-0.02)e2 | (1.02+/-1.33)e2 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Mar 23, 2026