| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -0.008 | 8.697e-04 | (2.12+/-0.02)e2 | 0.66 +/- 0.63 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -0.007 | 8.476e-04 | (2.13+/-0.02)e2 | 0.71 +/- 0.62 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | -0.006 | 0.002 | (1.53+/-0.04)e2 | 0.62 +/- 1.15 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -1.621 | 0.058 | (5.52+/-1.52)e2 | -39.77 +/- 34.67 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -9.048e-04 | 0.002 | (2.63+/-0.04)e2 | -0.37 +/- 1.37 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.018 | 0.003 | (2.89+/-0.06)e2 | 1.45 +/- 1.12 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.019 | 0.003 | (2.89+/-0.07)e2 | 1.76 +/- 1.24 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.018 | 0.003 | (2.92+/-0.06)e2 | 1.61 +/- 1.20 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.005 | 0.001 | (2.49+/-0.03)e2 | -0.02 +/- 0.96 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.004 | 9.811e-04 | (2.45+/-0.02)e2 | -0.10 +/- 0.89 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.015 | 0.003 | (3.03+/-0.06)e2 | -2.71 +/- 1.88 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.016 | 0.002 | (2.96+/-0.06)e2 | -2.57 +/- 1.87 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 0.002 | 0.001 | (3.45+/-0.03)e2 | 0.04 +/- 0.25 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | -0.007 | 9.056e-04 | (1.94+/-0.02)e2 | 0.82 +/- 0.55 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | -0.007 | 9.093e-04 | (1.94+/-0.02)e2 | 0.77 +/- 0.55 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Sep 06, 2026