| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | 0.610 | 0.021 | (2.09+/-0.03)e2 | -0.89 +/- 1.00 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | 0.628 | 0.021 | (2.10+/-0.03)e2 | -0.85 +/- 0.98 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.469 | 0.025 | (1.48+/-0.03)e2 | 0.05 +/- 1.06 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | 104.091 | 1.366 | (3.52+/-2.49)e2 | 11.58 +/- 25.24 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | 0.566 | 0.035 | (2.57+/-0.04)e2 | -0.55 +/- 1.42 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | -0.033 | 0.047 | (2.83+/-0.05)e2 | 0.50 +/- 1.65 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | -0.013 | 0.050 | (2.83+/-0.06)e2 | -0.16 +/- 1.85 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | -0.021 | 0.046 | (2.86+/-0.05)e2 | -0.13 +/- 1.68 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | 0.207 | 0.027 | (2.44+/-0.02)e2 | 0.92 +/- 0.86 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | 0.601 | 0.024 | (2.42+/-0.03)e2 | -0.63 +/- 1.10 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | -0.016 | 0.049 | (2.97+/-0.06)e2 | 1.50 +/- 2.06 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | -0.158 | 0.048 | (2.88+/-0.05)e2 | 2.30 +/- 2.00 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | 2.109 | 0.104 | (3.39+/-0.12)e2 | -1.83 +/- 3.72 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.523 | 0.020 | (1.92+/-0.02)e2 | -0.68 +/- 0.90 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.552 | 0.020 | (1.91+/-0.02)e2 | -0.85 +/- 0.91 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jul 21, 2026
Last Site Modification: Sep 30, 2021