| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| eb1ci | off | -2.897e-06 | 6.722e-06 | 0.33 +/- 0.18 | -(3.51+/-84.61)e-5 | AMP | BATT 1 CHARGE CURRENT | No Violation Check | on | 2.643e-04 | 3.187e-04 | 0.53 +/- 0.58 | (0.00+/-0.00)e0 | No Violation Check |
| eb1di | off | -4.259e-05 | 2.620e-05 | 0.07 +/- 0.69 | (2.15+/-246.00)e-5 | AMP | BATT 1 DISCHARGE CURRENT | No Violation Check | on | 1.556e-04 | 0.001 | 0.82 +/- 2.65 | (0.00+/-0.00)e0 | No Violation Check |
| eb1v | off | 6.971e-05 | 3.915e-06 | 32.35 +/- 0.10 | -(5.84+/-2.90)e-4 | V | BATT 1 VOLTAGE | No Violation Check | on | -4.510e-04 | 1.643e-04 | 32.19 +/- 0.32 | (0.00+/-0.00)e0 | No Violation Check |
| eb2ci | off | 2.184e-06 | 6.456e-06 | 0.28 +/- 0.17 | (5.45+/-81.42)e-5 | AMP | BATT 2 CHARGE CURRENT | No Violation Check | on | 2.714e-04 | 3.069e-04 | 0.48 +/- 0.56 | (0.00+/-0.00)e0 | No Violation Check |
| eb2di | off | -4.318e-05 | 2.643e-05 | 0.06 +/- 0.69 | (9.29+/-24.40)e-4 | AMP | BATT 2 DISCHARGE CURRENT | No Violation Check | on | 6.100e-05 | 0.001 | 0.76 +/- 2.60 | (0.00+/-0.00)e0 | No Violation Check |
| eb2v | off | 2.934e-06 | 3.237e-06 | 32.30 +/- 0.09 | (1.21+/-1.67)e-4 | V | BATT 2 VOLTAGE | No Violation Check | on | -2.283e-04 | 1.458e-04 | 32.12 +/- 0.27 | (0.00+/-0.00)e0 | No Violation Check |
| eb3ci | off | 5.593e-06 | 4.888e-06 | 0.27 +/- 0.13 | -(2.17+/-6.58)e-4 | AMP | BATT 3 CHARGE CURRENT | No Violation Check | on | 1.884e-04 | 2.146e-04 | 0.41 +/- 0.39 | (0.00+/-0.00)e0 | No Violation Check |
| eb3di | off | -4.401e-05 | 2.660e-05 | 0.06 +/- 0.70 | (4.49+/-24.22)e-4 | AMP | BATT 3 DISCHARGE CURRENT | No Violation Check | on | 1.054e-04 | 0.001 | 0.76 +/- 2.63 | (0.00+/-0.00)e0 | No Violation Check |
| eb3v | off | 1.334e-05 | 3.693e-06 | 32.02 +/- 0.10 | (2.95+/-2.70)e-4 | V | BATT 3 VOLTAGE | No Violation Check | on | -2.938e-04 | 1.709e-04 | 31.83 +/- 0.32 | (0.00+/-0.00)e0 | No Violation Check |
| ecnv1v | -7.727e-07 | 6.581e-07 | 15.03 +/- 0.02 | (7.21+/-90.64)e-6 | V | CONV 1 +15V OUTPUT | No Violation Check | |
| ecnv2v | -1.088e-06 | 5.620e-07 | 14.96 +/- 0.01 | -(1.19+/-6.54)e-5 | V | CONV 2 +15V OUTPUT | No Violation Check | |
| ecnv3v | -4.047e-07 | 2.223e-07 | 15.39 +/- 0.01 | -(9.16+/-22.39)e-6 | V | CONV 3 +15V OUTPUT | No Violation Check | |
| eepa5v | 2.539e-07 | 7.243e-07 | 5.25 +/- 0.02 | -(5.14+/-8.59)e-5 | V | +5V RCTU_EP A | No Violation Check | |
| eepb5v | 3.103e-07 | 3.502e-07 | 0.04 +/- 0.01 | (2.59+/-4.29)e-5 | V | +5V RCTU_EP B | No Violation Check | |
| eochrgb1 | -2.988e-07 | 1.579e-07 | 1.00 +/- 0.00 | (1.57+/-78.43)e-7 | na | BATT 1 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb2 | -3.140e-07 | 1.548e-07 | 1.00 +/- 0.00 | -(1.95+/-7.49)e-6 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eochrgb3 | -3.756e-07 | 1.808e-07 | 1.00 +/- 0.01 | -(2.88+/-10.48)e-6 | na | BATT 2 SOC RANGE (INTEGER 0 TO 10000 = 0 TO 100 ) | No Violation Check | |
| eoesac1c | -2.426e-05 | 1.184e-04 | 11.76 +/- 1.17 | -0.00 +/- 0.00 | na | -Y SOLAR ARRAY CURRENT - COUNTS (ESAMYI) | No Violation Check | |
| eoesac2c | -1.729e-05 | 1.126e-04 | 11.37 +/- 1.11 | -0.00 +/- 0.00 | na | +Y SOLAR ARRAY CURRENT - COUNTS (ESAPYI) | No Violation Check | |
| eoeb1dic | -1.137e-04 | 4.466e-05 | 0.04 +/- 0.44 | -(1.20+/-2.91)e-4 | AMP | TTERY 1 DISCHARGE CURRENT - COUNTS (EB1DI) | No Violation Check | |
| eoeb1vc | 3.514e-05 | 1.700e-05 | 32.54 +/- 0.17 | (1.32+/-25.71)e-5 | na | BATTERY 1 VOLTAGE - COUNTS | No Violation Check | |
| eoeb2cic | 1.657e-05 | 8.494e-06 | 0.26 +/- 0.08 | -(1.41+/-0.69)e-4 | na | BATTERY 2 CHARGE CURRENT - COUNTS ( EB2CI) | No Violation Check | |
| eoeb2vc | 7.789e-05 | 1.500e-05 | 32.26 +/- 0.15 | -(4.39+/-2.31)e-4 | na | VOLTAGE - COUNTS | No Violation Check | |
| eoeb3cic | 2.123e-05 | 7.616e-06 | 0.26 +/- 0.07 | -(1.47+/-0.83)e-4 | na | BATTERY 3 CHARGE CURRENT - COUNTS ( EB3CI) | No Violation Check | |
| eoeb3vc | 2.048e-05 | 1.448e-05 | 32.17 +/- 0.14 | -(3.62+/-2.27)e-4 | na | BATTERY 3 VOLTAGE - COUNTS | No Violation Check | |
| eoecnv1c | 1.759e-06 | 4.530e-06 | 14.97 +/- 0.04 | -(6.67+/-7.98)e-5 | na | PCU CONVERTER 1: +15V OUTPUT - ANALOG (ECNV1V) | No Violation Check | |
| eoecnv2c | -9.008e-06 | 4.320e-06 | 14.93 +/- 0.04 | (1.27+/-0.78)e-4 | na | PCU CONVERTER 2: +15V OUTPUT - ANALOG (ECNV2V) | No Violation Check | |
| eoecnv3c | 3.394e-06 | 4.255e-06 | 15.36 +/- 0.04 | (1.09+/-0.67)e-4 | na | PCU CONVERTER 3: +15V OUTPUT - ANALOG (ECNV3V) | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Jul 21, 2026
Last Site Modification: Sep 30, 2021