Back to Top

HRCTEMP
Static Version: Max --- Full Range

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.4120.009(2.95+/-0.08)e2-0.14 +/- 0.08KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.3440.005(2.95+/-0.03)e2-0.07 +/- 0.11KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.3530.010(2.88+/-0.08)e2-0.16 +/- 0.07KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.3730.008(2.88+/-0.07)e2-0.09 +/- 0.08KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -0.4470.009(2.88+/-0.08)e2-0.11 +/- 0.07KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.6280.012(2.89+/-0.11)e2-0.20 +/- 0.09KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.5430.011(2.85+/-0.10)e2-0.22 +/- 0.08KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.0170.006(2.92+/-0.05)e2-0.16 +/- 0.10KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.0740.007(2.94+/-0.06)e2-0.16 +/- 0.10KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.2420.007(2.86+/-0.06)e2-0.09 +/- 0.09KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Dec 23, 2025
Last Site Modification: Sep 30, 2021