Back to Top

HRCTEMP
Static Version: Mean --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -4.0250.056(2.86+/-0.10)e20.30 +/- 0.73KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 0.3220.027(2.96+/-0.03)e20.34 +/- 0.98KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -4.1990.060(2.78+/-0.11)e2-0.11 +/- 0.86KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -3.5580.049(2.80+/-0.09)e2-0.18 +/- 0.55KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -4.4130.059(2.78+/-0.11)e2-0.11 +/- 0.64KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -5.5150.080(2.75+/-0.14)e2-0.99 +/- 1.15KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -5.0560.074(2.73+/-0.13)e2-0.76 +/- 1.19KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -1.9620.033(2.87+/-0.05)e20.35 +/- 0.90KPMT 1 TEMPERATURENo Violation Check
2pmt2t -2.3850.038(2.88+/-0.06)e20.15 +/- 0.93KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -2.4060.038(2.80+/-0.06)e20.13 +/- 0.71KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Sep 07, 2026
Last Site Modification: Sep 30, 2021