Back to Top

HRCTEMP
Static Version: Mean --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt -0.0056.054e-04(2.79+/-0.01)e2-0.07 +/- 0.37KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt -0.0066.203e-04(2.76+/-0.01)e2-0.24 +/- 0.37KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -0.0118.672e-04(2.71+/-0.02)e20.25 +/- 0.47KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -0.0065.034e-04(2.74+/-0.01)e2-0.04 +/- 0.30KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -0.0065.881e-04(2.70+/-0.01)e2-0.50 +/- 0.36KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -0.0160.001(2.67+/-0.02)e2-0.23 +/- 0.69KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -0.0170.001(2.64+/-0.03)e2-0.15 +/- 0.74KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -0.0109.394e-04(2.85+/-0.02)e20.24 +/- 0.51KPMT 1 TEMPERATURENo Violation Check
2pmt2t -0.0109.289e-04(2.85+/-0.02)e20.17 +/- 0.51KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -0.0116.806e-04(2.76+/-0.02)e20.01 +/- 0.44KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Jun 02, 2026
Last Site Modification: Sep 30, 2021