Back to Top

MUPS
Static Version: Max --- Last Five years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
aothrst1 1.868e+0359.055(7.20+/-7.50)e3(1.96+/-0.31)e3CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS1 OR MUPS1)No Violation Check
aothrst2 -15.2157.624(1.81+/-8.53)e2(7.45+/-2.89)e-8CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS2 OR MUPS2)No Violation Check
aothrst3 472.77933.285(4.00+/-3.83)e3(4.36+/-1.53)e2CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS3 OR MUPS3)No Violation Check
aothrst4 1.034e+0348.735(5.40+/-5.79)e3(7.79+/-2.14)e2CNTSACCUMULATED THRUSTER ON-TIME COUNTS (RCS4 OR MUPS4)No Violation Check
pcm01t 3.1440.053(3.43+/-0.08)e2-0.39 +/- 2.56KPCM TEMP 01No Violation Check
pcm02t 3.1470.053(3.43+/-0.08)e2-0.48 +/- 2.53KPCM TEMP 02No Violation Check
pcm03t 3.1370.055(3.44+/-0.09)e2-0.48 +/- 2.52KPCM TEMP 03No Violation Check
pcm04t 3.1200.052(3.43+/-0.08)e2-1.34 +/- 2.52KPCM TEMP 04No Violation Check
pfdm101t -0.0510.007(2.93+/-0.01)e2-0.24 +/- 0.25KFDM1 TEMP 01No Violation Check
pfdm102t -0.1660.012(2.94+/-0.01)e2-0.36 +/- 0.44KFDM1 TEMP 02No Violation Check
pfdm201t 0.1270.008(2.90+/-0.01)e2-0.44 +/- 0.26KFDM2 TEMP 01No Violation Check
pfdm202t 0.1280.006(2.89+/-0.01)e2-0.25 +/- 0.20KFDM2 TEMP 02No Violation Check
pffp01t 1.5540.047(3.13+/-0.06)e21.68 +/- 1.78KFFP TEMP 1No Violation Check
pftank1t 2.0120.021(3.14+/-0.04)e2-0.32 +/- 1.00KFUEL TANK TEMP 01No Violation Check
pftank2t 2.1270.020(3.15+/-0.05)e2-0.38 +/- 0.97KFUEL TANK TEMP 02No Violation Check
pftankip 12.6460.136(2.08+/-0.03)e3-5.77 +/- 6.24PSIAFUEL TANK INLET PRESSURENo Violation Check
pftankop 14.9350.141(2.06+/-0.03)e3-2.29 +/- 6.72PSIAFUEL TANK OUTLET PRESSURENo Violation Check
phetankp -2.094e-08999.000(6.30+/-0.00)e2(6.62+/-6.41)e-8PSIAHE TANK PRESSURENo Violation Check
phetankt 3.5000.050(3.45+/-0.09)e2-0.26 +/- 2.14KHE TANK OUTLET TEMPNo Violation Check
phofp1t -0.1630.012(3.04+/-0.01)e20.14 +/- 0.24KHE/OX FILL PANEL TEMP 1No Violation Check
pline01t 1.0330.021(2.96+/-0.03)e20.40 +/- 0.97KPROP LINE TEMP 01No Violation Check
pline02t 2.8550.069(3.49+/-0.09)e2-1.98 +/- 2.38KPROP LINE TEMP 02No Violation Check
pline03t 1.4920.077(3.44+/-0.09)e2-0.75 +/- 2.35KPROP LINE TEMP 03No Violation Check
pline04t 2.5140.079(3.30+/-0.10)e2-1.86 +/- 3.16KPROP LINE TEMP 04No Violation Check
pline05t 2.4990.045(3.25+/-0.07)e20.23 +/- 2.04KPROP LINE TEMP 05No Violation Check
pline06t 2.4100.041(3.16+/-0.06)e20.01 +/- 1.90KPROP LINE TEMP 06No Violation Check
pline07t 1.6160.042(3.12+/-0.06)e20.82 +/- 1.64KPROP LINE TEMP 07No Violation Check
pline08t -0.0800.006(2.97+/-0.01)e2-0.03 +/- 0.20KPROP LINE TEMP 08No Violation Check
pline09t -0.4600.029(3.14+/-0.03)e20.94 +/- 1.17KPROP LINE TEMP 09No Violation Check
pline10t 0.1540.010(3.08+/-0.01)e20.12 +/- 0.42KPROP LINE TEMP 10No Violation Check
pline11t -0.0670.013(2.95+/-0.02)e20.49 +/- 0.76KPROP LINE TEMP 11No Violation Check
pline12t 0.6970.015(2.95+/-0.02)e20.95 +/- 0.71KPROP LINE TEMP 12No Violation Check
pline13t -0.2010.016(2.87+/-0.02)e20.92 +/- 0.56KPROP LINE TEMP 13No Violation Check
pline14t -0.0110.011(2.94+/-0.01)e2-0.23 +/- 0.42KPROP LINE TEMP 14No Violation Check
pline15t 0.2560.016(2.96+/-0.02)e20.87 +/- 0.74KPROP LINE TEMP 15No Violation Check
pline16t 1.1500.023(3.13+/-0.03)e2-1.24 +/- 1.03KPROP LINE TEMP 16No Violation Check
pm1thv1t 1.9350.077(3.67+/-0.09)e2-0.31 +/- 2.58KMUPS 1 THRUSTER VALVE 01 TEMPNo Violation Check
pm1thv2t 2.1340.070(3.68+/-0.09)e2-1.73 +/- 2.35KMUPS 1 THRUSTER VALVE 02 TEMPNo Violation Check
pm2thv1t 1.5570.161(3.61+/-0.18)e21.53 +/- 5.12KMUPS 2 THRUSTER VALVE 01 TEMPNo Violation Check
pm2thv2t 2.1130.206(3.55+/-0.23)e2-3.85 +/- 6.66KMUPS 2 THRUSTER VALVE 02 TEMPNo Violation Check
pm3thv1t -0.2490.010(3.08+/-0.01)e20.18 +/- 0.25KMUPS 3 THRUSTER VALVE 01 TEMPNo Violation Check
pm3thv2t -0.2420.010(3.07+/-0.01)e20.23 +/- 0.26KMUPS 3 THRUSTER VALVE 02 TEMPNo Violation Check
pm4thv1t -0.1650.019(3.07+/-0.02)e20.25 +/- 0.62KMUPS 4 THRUSTER VALVE 01 TEMPNo Violation Check
pm4thv2t -0.1290.016(3.03+/-0.02)e20.33 +/- 0.52KMUPS 4 THRUSTER VALVE 02 TEMPNo Violation Check
pmfp01t 2.4840.042(3.19+/-0.07)e2-0.84 +/- 1.91KMFP TEMP 1No Violation Check
pmtank1t 2.6730.022(3.21+/-0.06)e2-0.10 +/- 1.37KMUPS TANK TEMP 1No Violation Check
pmtank2t 2.6520.025(3.20+/-0.06)e20.15 +/- 1.36KMUPS TANK TEMP 2No Violation Check
pmtank3t 2.6840.025(3.21+/-0.06)e2-0.25 +/- 1.38KMUPS TANK TEMP 3No Violation Check
pmtankp 21.0650.269(9.75+/-0.50)e2-5.99 +/- 7.61PSIAMUPS TANK PRESSURENo Violation Check
pxdm01t -0.3580.021(2.91+/-0.02)e21.65 +/- 1.03KODM TEMP 01No Violation Check
pxdm02t -0.7640.031(2.96+/-0.04)e22.48 +/- 1.45KODM TEMP 02No Violation Check
pxtank1t 0.0030.006(2.99+/-0.01)e2-0.06 +/- 0.29KOX TANK TEMP 01No Violation Check
pxtank2t -0.0310.007(3.00+/-0.01)e2-0.18 +/- 0.27KOX TANK TEMP 02No Violation Check
pxtankip -6.7900.042(1.87+/-0.01)e3-0.72 +/- 1.59PSIAOX TANK INLET PRESSURENo Violation Check
pxtankop 0.0430.043(1.92+/-0.00)e3-1.37 +/- 1.96PSIAOX TANK OUTLET PRESSURENo Violation Check