Back to Top

SIMELEC
Static Version: Min --- Last Three Months

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
agrndadc -3.481e-085.637e-08-(8.09+/-1.63)e-4(1.82+/-3.54)e-5VAnalog fround A/D convert readingNo Violation Check
fatabadc -7.443e-051.206e-044.97 +/- 0.35-0.02 +/- 0.04VFA Tab Position Sensor A/D ConverterNo Violation Check
n15vadc -1.257e-061.379e-07-15.02 +/- 0.00-(3.94+/-9.72)e-5V-15V Power Supply A/D Converter ReadingNo Violation Check
p15vadc 2.585e-072.515e-0714.96 +/- 0.00(1.05+/-2.15)e-4V+15V Power Supply A/D Converter ReadingNo Violation Check
p5vadc -3.449e-051.579e-064.94 +/- 0.01-(3.56+/-98.04)e-5V+5V Power Supply A/D Converter ReadingNo Violation Check
tsctabadc -7.154e-042.383e-044.89 +/- 0.69-0.05 +/- 0.11VTSC Tab Position Sensor A/D converterNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Oct 24, 2026
Last Site Modification: Sep 30, 2021