File |
$Source: /home/juda/www/hrc_flight/macros/RCS/hrcobs.html,v $ |
Version |
$Revision: 1.5 $ |
Last Update |
$Date: 1999/04/21 13:31:57 $ |
HRC CCB Status |
Approved |
HRCOBS Configuration
Description:
This sequence captures the logic that should be followed by the
Command Generation function within the OCC Off-line System to
configure the HRC for observations (i.e.the HRCOBS statement within the
Detailed Operations Time-line would be expanded via this
sequence). The specific settings requested for an observation are
passed into the HRCOBS statement by the HRC_MODE value of the Observation Request
(OR).
Notice that since we expect to use default settings for most
observations, this higher-level procedure will usually only send
commands to the HRC if there is a detector change (HRC-I to -S or
HRC-S to -I).
Cautions/Restrictions:
An HRC detector, either HRC-I or HRC-S, is expected to be operational
as a prerequisite to scheduling an HRCOBS statement. Thus, this higher
level sequence does not contain steps to go from the "Off" state.
Procedure
- If the HRC detector housing door is NOT OPEN
- If this observation uses a different detector than the current
detector
- If the detector is not currently configured with the default
settings
- If the shutters are not at the home position
- If the current detector is the HRC-I
- Else the current detector is the HRC-S
- If this observation does not use the default settings
- If non-default trigger threshold
- Send command 2LLDIATH with 2LLDIAT1 = TRIGGER_LEVEL
- If non-default range switch value
- Send command 2RSRFAAM with 2RSRFAA1 = RANGE_SWITCH_LEVEL
- If spectroscopy mode is "IMAGING"
- If anticoincidence vetoing is enabled
- If width vetoing is enabled
- If non-default width threshold
- Send command 2WDTHATH with 2WDTHAT1 = WIDTH_THRESHOLD
- If ULD vetoing is enabled
- If non-default ULD level
- Send command 2ULDIATH with 2ULDIAT1 = UPPER_LEVEL_DISC
- If center blanking is enabled
- If edge blanking is enabled
- If +Y shutter is not at "Home"
- If -Y shutter is not at "Home"
- Activate SCS #91 (HRC Dither Control)
$Log: hrcobs.html,v $
Revision 1.5 1999/04/21 13:31:57 juda
marked as Approved
Revision 1.4 1999/03/03 21:34:33 juda
changed links for files with name changes
Revision 1.3 1998/11/18 17:16:31 juda
moved "MCP HV Off" and "Terminate SCS#91" out of detector specific sections
Revision 1.2 1998/10/15 20:44:30 juda
replaced calls to pages for switch HRC-I to HRC-S and HRC-S to HRC-I with the necessary explicit line. This removes the MCP HV ramp-up activation and allows SCS #91 to do the ramp-up
Revision 1.1 1998/10/15 20:14:47 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356
E-mail: mjuda@cfa.harvard.edu